![ST ST25RU3993 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/st/st25ru3993/st25ru3993_user-manual_1355960048.webp)
Reader Settings
UM2268
48/68
UM2268 Rev 6
4.2.1
Diagnostic Sweep Function panel
In the Diagnostic Sweep Function panel, it is possible to run reflected power sweep
measurements across the select frequency range, or scan for the presence of an external
carrier or disturber.
•
Source
: Select one of the two available frequency sweep sources:
–
Reflected Power
–
Ext. Signal source.
•
Start
: Start frequency of the frequency sweep in MHz.
•
User defined manual frequency list
: By default the frequency sweep is done over the
current selected channel list of the reader. If checked, a user defined frequency sweep
could be executed.
•
Stop
: Stop frequency in MHz, where the sweep should stop.
•
Increment
: Defines the frequency step size for each consecutive measurement in
MHz.
•
Sweep
: Starts the frequency sweep with the defined source and frequency range.
Once the measurement is completed the result is displayed in a dedicated window:
Figure 46. Diagnostic sweep
Содержание ST25RU3993
Страница 6: ...List of tables UM2268 6 68 UM2268 Rev 6 List of tables Table 1 Document revision history 66...
Страница 11: ...UM2268 Rev 6 11 68 UM2268 Quick start guide 65 Figure 7 Device manager Detected ST25RU3993 reader board...
Страница 32: ...Register map UM2268 32 68 UM2268 Rev 6 Figure 30 Register Map...
Страница 34: ...Reader Settings UM2268 34 68 UM2268 Rev 6 4 1 Settings tab Figure 31 Reader Settings Settings tab...
Страница 38: ...Reader Settings UM2268 38 68 UM2268 Rev 6 Figure 35 Channel list dialog...
Страница 43: ...UM2268 Rev 6 43 68 UM2268 Reader Settings 65 Figure 40 RX filter dialog Figure 41 Rx option panel...
Страница 47: ...UM2268 Rev 6 47 68 UM2268 Reader Settings 65 4 2 Diagnostics Figure 45 Reader Settings Diagnostics tab...