![ST WELD MIG-100 MIG-135 MIG-135N MIG-175 MIG-195 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/st-weld/mig-100-mig-135-mig-135n-mig-175-mig-195/mig-100-mig-135-mig-135n-mig-175-mig-195_instruction-manual_1356254019.webp)
3
2 INSTALLATIONS
2-1.
Welding power source
Type
MIG-100
MIG-135
MIG-135N
MIG-175
MIG-195
Power supply
220V +/-15%
220V +/-15%
220V +/-15%
220V +/-15%
220V +/-15%
Frequency
50-60Hz
50-60Hz
50-60Hz
50-60Hz
50-60Hz
Phase
1PH
1PH
1PH
1PH
1PH
Rated
input(KVA)
3.25
4.1
4.8
(
MIG
)
/5.1
(
MMA
)
6.8
(
MIG
)
/7.2
(
MMA
)
7.6
(
MIG
)
/7.8
(
MMA
)
Open circuit
voltage(V)
44
44
55
55
55
Amperage
range(A)
40-100
40-120
40-135
(
MIG
)
/40-
120
(
MMA
)
40-170
(
MIG
)
/40-
160
(
MMA
)
40-190
(
MIG
)
/40-
170
(
MMA
)
Rated Duty
cycle (%)
X=60%
100A/19V
X=100%
80A/18V
X=60%
120A/20V
X=100%
95A/19V
X=60%
135A/20.75V
X=100%
105A/19.25V
X=30%
170A/22.5V
X=60%
120A/20V
X=30%
190A/23.5V
X=60%
130A/20.5V
Rated working
voltage(V)
15.5-19
15.5-20
15.5-20.75
(
MIG
)
21.6-24.8
(
MMA
)
16-22.5
(
MIG
)
21.6-26.4
(
MMA
)
16-23.5
(
MIG
)
21.6-26.8
(
MMA
)
Efficiency
0.73
0.73
0.73
0.73
0.73
Power factor
0.8
0.8
0.8
0.8
0.8
Insulation
Grass
F
F
F
F
F
Weight(kg)
10
10
10
11.4
11.4
Dimension(L x
W x H)(MM)
480*220*340
480*220*340
480*220*340
480*240*37
0
480*240*370
CAUTION
WELDING LONGER THAN RATED DUTY CYCLE CAN DAMAGE TORCH AND VOID WARRANTY.