FLOOR PROTECTION
The stove must be installed on a non-combustible protective pad.
Freestanding stoves will have either a pedestal or cast legs (Prescott Series) or Pedestal only (Afton
Bay stoves).
Insert models may be placed directly on the noncombustible hearth of a fireplace.
Floor protection is required for the area directly under the stove and extending 6” beyond the front of
the stove as shown.
Models: Prescott EX,
Figure(s):
From:
Prescott EXL, Afton Bay, York
14, 16B
Sides of stove
1”
14, 16A, B
Back of stove (rear face of control box)
1”
13
Corner of stove
1”
13
Vent pipe
3”
16
Stove to mantel
12”
16
Floor protection: Front(from faceplate)
6”
12
Floor protection: Sides & back of stove
0”
15
Alcove: Vertical to Combustibles
16”
17
Alcove: Sides
1”
17
Alcove: Back
1”
MINIMUM CLEARANCES (INCHES) TO COMBUSTIBLE MATERIAL
19
Fig 12