SCF-050 Manual
49
Solution:
If the fire is out
, re-light the Furnace.
If the fire is still burning
make sure all
doors are securely latched
and
hold down the On/Off
button (approximately 5
seconds) until Furnace starts up again. This will re-start the Furnace in the start-up
program. Occasionally use the auger button to manually feed fuel until the auto-
feed takes over (Auto feed will start 5 minutes after the Furnace has been
restarted).
5.
My Furnace isn’t burning and the number 3 LED light is blinking.
This diagnostic light
indicates that the Proof of Fire Switch no longer senses a fire in the Furnace. First check to see if
there are pellets in the hopper. If there are pellets in the hopper, why did the Furnace go out?
a.
Unburned fuel in the burnpot means the fire went out before the auger quit
feeding.
b.
A power Failure could also cause this. If the furnace is still hot when the power
comes back on, the feed system will resume. If the fire had gone out in the pot,
the feed would continue to run until the Proof of Fire switch dropped out and shut
the Furnace down.
Solution: Too much Combustion Air on the pilot setting.
Adjust the air damper. (See section
covering an
Unbalanced Burnpot).
Fuel would still feed until the P.O.F. switch eventually shuts
the Furnace down. Adjust the damper. (See
Damper Adjustment
in the Operations Manual)
c.
The Burnpot being empty will mean the auger quit feeding fuel while there was
still a fire in the burnpot. Check to see if there is fuel in the hopper. If the hopper
is empty, fill the hopper and re-light the Furnace.
d.
If there is fuel in the hopper check to see if there is an obstruction in the auger
system or if the auger set screw is loose.
Solution:
Remove obstruction and re-light the Furnace or tighten the setscrew on the
auger shaft.
6.
My Furnace isn’t burning and the #2 and #3 LED lights are blinking.
This means the high
Limit has shut the Furnace down. The Convection Blower could be defective or may need
cleaning. The high limit switch may be also defective. It is best to call your dealer for support
when trying to troubleshoot the High Limit Switch. Do not use your Furnace if the High Limit
switch frequently trips.
7.
I lit the Furnace and the # 2 light started blinking and smoke spills out of the Furnace.
How
do I get the Furnace to quit smoking?