Step 15: Centering the Pitch Potentiometer
Prepare a thin permanent marker or a soft pencil. You are going to determine the
exact mid-points for all three polarized potentiometers.
For your convinience, you could also outline the pointer lines on the Wave, AM, Attack
and Decay shafts.
Set the module to the settings pictured above. Monitor the output frequency with an
oscilloscope, frequency meter, tuner or your ears and turn the Pitch shaft counter-
clockwise until the frequency stops changing. This will be the mid-point for the Pitch
knob. Now draw a straight line on the shaft's edge, pointing exactly to the top. Later,
this line will help you to put on the respective knob correctly.