background image

6

the buttons BTS/BTC 750-...  and
BTLM 650-... for actuation can be
manually programmed. For pro-
gramming a key and an LED as a
status display and functional testing
are available. 

Defining control buttons for
actuation of the BSE 650-...  .

Important!

There is no BTLM 650-... or 
BTLE 050-... activated. The 
BSE 650-... can only be programmed
when the YR system is active. 

Switch BSG 650-... to the pro-
gramming mode;

The status LED at the BSG 650-...
flashes evenly.
Fig. 2

Switch the BSE 650-... you wish
to program to the programming
mode;

The status LED flashes very slowly.
Fig. 3

Pick up the receiver of the
BTS/BTC 750-... at which you
wish to program a button; 

The call connected signal sounds. 
Fig. 4

Press the button you wish to
program; 

An acknowledgement tone sounds
in the receiver. Replace the receiver. 
Fig. 5

If you wish this BSE 650-... to be
actuated from several 
BTS/BTC 750-... units, repeat the
steps described for Fig. 4 and 5 until
all the telephones / BTLM units are
programmed. 

Switch off the programming
mode at the BSG 650-... ;

Status LED is extinguished, opera-
ting status of the overall system. 
Fig. 6

or process other programming
points. 

Defining call buttons for actua-
tion of the BSE 650-... which
actuate the BSE 650-... with the
function „secondary signal con-
troller“ in parallel to a 
BTS/BTC 750-... .

Important!

No BTLM 650-... or BTLE 051-... is
active. 
If you wish for an additional signal
to be issued when actuating the call
button, in parallel to the call signal
at the BTS/BTC 750-..., the swit-
ching contact in the BSE 650-... can
be used for actuation. 
However, the call button at the door
loudspeaker must already be pre-
viously assigned to the relevant
BTS/BTC 750-... . 
At a BSE 650-... 

either

a control

function 

or

a parallel connected

NSC function can be programmed.
Double assignment is not possible.

Switch the BSG 650-... to the
programming mode;

The status LED flashes evenly.
Fig. 2

Switch the BSE 650-... you wish
to program to the programming
mode;

The status LED flashes very slowly.
Fig. 3

Press the call button you wish to
program at the door loudspea-
ker;

The status LED at the BSE 650-... 
briefly flashes faster and the door
call sounds at the parallel
BTS/BTC 750-... .
Fig. 7

Switch off the programming
mode at the BSG 650-... 

The status LED goes out, operating
status of the overall system.
Fig. 6

or process other programming
points.

Deleting the control button for
actuation of the BSE 650-... .

Buttons which act on a BSE 650-...
are generally individually deleted,
i.e. when the BSE is in the delete
mode, each button you wish to
delete must be selectively accessed
and deleted. 
Call buttons with NSC function can
only be overwritten. In order to
delete a button programmed with
an NSC function, this must first be
overwritten with a button at the
BTS/BTC750-... (control function).
The key can subsequently be dele-
ted. 

Switch the BSG 650-... to the
programming mode; 

(if not already switched on)
The status LED flashes evenly.
Fig. 2

Switch the BSE 650-... you wish
to program to the programming
mode;

The status LED flashes very slowly.
Fig. 3

Switch the BSE 650-... to the
delete mode;

The status LED stays alight
Fig. 8

Lift the receiver at the 
BTS/BTC 750-... from which you
wish to delete the button; 

The call connected tone sounds.
Fig. 4

Press the button you wish to
delete; 

You will hear an acknowledgement
tone in the receiver. If you wish to
delete the button in several 
BTS/BTC 750-... units which actuate
this BSE 650-... , repeat the steps
described under Fig. 4 and Fig. 5
until all telephone buttons have
been deleted. 
Fig. 5

Содержание SIEDLE BSE 650-0

Страница 1: ...nheit BSE 650 0 Bus switching unit BSE 650 0 Unité de commutation bus BSE 650 0 Unità di comando bus BSE 650 0 Bus schakel eenheid BSE 650 0 Busstyreenheden BSE 650 0 Buss kopplings enhet BSE 650 0 Sběrnicová spínací jednotka BSE 650 0 ...

Страница 2: ......

Страница 3: ...1 2 3 4 5 6 4 Sek ON 1 Sek OFF ...

Страница 4: ...7 8 4 Sek 1 Sek 10 9 4 Sek 4 Sek OFF 1 Sek 11 ...

Страница 5: ...12 13 14 15 4 Sek 4 Sek 4 Sek 1 59 Sek 1 Min ...

Страница 6: ...id interference ensure that the heavy and light current conductors are separately routed observing a distance of 10 cm See also the rele vant national and local regulations Do not mount these devices in boiler rooms Safety remark In accordance with DIN VDE 0100 Part 410 Section 411 1 3 steps must be taken to observe a secure separation between bus lines and mains voltage lines Bus cores mains core...

Страница 7: ... 750 At a BSE 650 either a control function or a parallel connected NSC function can be programmed Double assignment is not possible Switch the BSG 650 to the programming mode The status LED flashes evenly Fig 2 Switch the BSE 650 you wish to program to the programming mode The status LED flashes very slowly Fig 3 Press the call button you wish to program at the door loudspea ker The status LED at...

Страница 8: ...the button at the BSE is not actuated for this period the BSE 650 automatically swit ches out of the programming mode The relay can be programmed for the switching function in two diffe rent ways Toggle mode On off function every time the but ton is actuated as delivered status or Time relay When actuating the button the relay switches for the programmed time retriggering possible Toggle function ...

Страница 9: ...ts Motors max 3 A Light bulbs max 1300 W Energy saving lamps max 18 x Silvania 7 W or 12 x Osram 11 W Fluorescent lamps uncorrected cos ϕ 0 5 max 800 VA Duo fluorescent lamps max 1200 VA Parallel corrected fluorescent lamps max 400 VA Iron core transformers for low vol tage halogen lamps max 1000W Electronic transformers for low vol tage halogen lamps max 1300 W Protection system IP 20 Ambient tem...