Manual
DoorCom IP

DCIP 600-0

Содержание DoorCom IP DCIP 600-0

Страница 1: ...Manual DoorCom IP DCIP 600 0 ...

Страница 2: ...DCIP 600 0 Terminals DCIP 600 0 14 LED display SIVS 600 IPVS 600 15 Block diagrams 16 DCIP 600 up to 4 users 18 DCIP 600 with DCA 740 20 DCIP 600 with TME 645 22 DCIP 600 with COM 611 24 DCIP 600 with COM 611 and AEM 645 26 DCIP 600 with DRM 611 28 6 Commissioning DCIP 600 30 Multicasting 31 Configuration software DCIP CO 32 Software client DCIP SC 34 7 Setting the speech volume level adjustment D...

Страница 3: ...e mains switch must be provided in the building installation with a contact opening of at least 3 mm Ensure that the connection point in the building installation is fused with max 16 A When planning the required distributor space for switch panel mounted devices must be taken into account External voltages 30 V AC DC must not be injected into the in house telephones Devices with 230 V connection ...

Страница 4: ...n of the SIVS 600 Software Client DCIP SC 600 for installation on PC users intended to receive door calls Power supply The DCIP 600 SET works with 24 28 V supply voltage An optionally connected DCA 740 01 is supplied from the SIVS 600 The a b public network interface is supplied from the TC system It is not possible to connect an individual public network telephone directly to the a b line of the ...

Страница 5: ...t additionally be installed at an analog PBX extension of a telephone system One DCIP 600 each is required per door station This can be used to call a maximum of 49 different users For 4 PC users the Software Client is included in the scope of delivery of the DCIP 600 Each additional PC user requires a licence for the Software Client DCIP SC 600 0 DCIP 600 System free link with connection of a tel...

Страница 6: ...are applied In general an IPVS can manage a maximum of 50 registrations Every PC user to which a door call has been established currently occu pies 2 registrations in the IPVS If no groups are created a maximum of 49 single PC users can be integrated If one of these PC users is called it currently occupies 2 registrations the others occupy only one each In total this adds up to 1 2 48 50 which is ...

Страница 7: ...client program The hardware on which the server runs is known as the host Subnet mask The subnet mask also known as network mask is a bit mask which separates an IP address into a network and a device or host section It is used in IP networks in order to make routing decisions System free The DCIP 600 is operated with a system free connection This means that the door loudspeaker works with line si...

Страница 8: ...ption 25 mA per call button module TM 612 Used as call buttons 1 4 directly at the SIVS 600 TME 645 0 Call button module extension with interface to the Vario bus for max 8 TME 645 Suitable for connection of call button module BTM 650 A maximum of 16 bus call button modules can be connected per TME 645 With an acoustic signal which sounds on button assignment The call button modules are connected ...

Страница 9: ...habetical input module with keypad A I Input unit for alphanumerical selection of PC users For use in Siedle Multi systems only in conjunction with the TLC 640 02 COM 611 01 DIM 640 0 and SIVS 600 Operating voltage 12 V AC DC Current consumption max 100 mA 4 Components for DCIP 600 Input module camera module DRM 611 0 Display call module as an input unit with 4 line display for placing door calls ...

Страница 10: ...ed for configuration of the system interface video server with software DCIP CO 600 version 1 1 or higher IPVS 600 0 System interface video server Processing and adjustment of audio and video transmission of data audio and video to the IP network Dimensions 112 x 85 x 40 mm DCA 740 01 The DoorCom Analog DCA 740 01 can be connected to a universal a b interface In conjunction with the DCIP 600 740 i...

Страница 11: ...figuration software PC program for set up and programming of the Siedle interface video server SIVS 600 Programming takes place via the USB programming interface PRI 602 USB configuration software version 1 1 or higher Commissioning software for the administrator CD contains DoorCom IP Software Client DCIP SC 600 0 DoorCom IP Configuration software DCIP CO 600 0 DoorCom IP Manual Siedle default co...

Страница 12: ... COM 611 AEM 645 TME 645 or DRM 611 possible Dimensions 144 x 130 x 55 mm TLM LL 611 01 Door loudspeaker module for interfacing at a symmetrical or asymmetrical line interface with integrated electret microphone and loudspeaker Integrated echo compensation for full duplex operation Potential free light button capable of illumination and controllable volume Power supply 15 28 V DC max 100 mA Line I...

Страница 13: ...13 ...

Страница 14: ...ights up in green with an existing network connection g LED T flashes orange on data transmission via the network Terminals IPVS 600 0 h Video input 1Vss from the SIVS 600 i Audio Line In to the SIVS 600 j Terminal plug for control signals k Audio Line Out to the SIVS 600 Terminals SIVS 600 a Video signal 1 Vss cinch jack b Terminating resistor 75 Ohm ON OFF c IN video signal 1 Vss input D Video s...

Страница 15: ...possibly new software update or exchange ON Slow flashing Variobus address error error remedy possible on site ON Fast flashing The 15 V power supply terminal bv cv is overloaded Error remedy possible on site OFF OFF If supply voltage is definitely connected the device is defective Exchange Frequencies Slow appr 2 Hz fast appr 16 Hz LED signalling IPVS 600 The underneath of the IP video server IPV...

Страница 16: ...Tö Door release contact potential Tö Free max 24 V 1 A Li Light contact USP Universal Switch Port bn1 Line signal to the door station bn2 outgoing an1 Line signal from an2 door station incoming n1 NF signal for n2 connected DCA 740 01 Block diagram TLM LL 611 01 Terminal for supply voltage L Lighting light button an1 Microphone signal an2 Mu Muting bn1 Loudspeaker signal bn2 T1 Potential free cont...

Страница 17: ...r loudspeaker for camera on With DoorCom IP the contact is permanently active Potential is switched via the UPS terminal VKA Actuation of camera distributor M is switched A1 A1 Potential free contact for additional applications b c Power supply 12 V AC for heating 5 Terminals CMC 612 0 ...

Страница 18: ...18 Device requirement Remarks red black 5 Installation DCIP 600 system free up to 4 users ...

Страница 19: ...utton from the door station Every PC user to which a door call has been established occupies currently 2 registrations in the IPVS Remarks a Door release 12 V AC use at least 20 Ohm e g TÖ 615 b The NG 600 0 can also take over the power supply to existing on site call buttons A voltage of 12 V AC max 200 mA is available for the lighting if a door release with an impedance of at least 20 Ohm is use...

Страница 20: ...20 5 Installation DCIP 600 system free up to 4 users with DCA 740 ...

Страница 21: ...rs are possible Connection of the COM 611 is possible in order to call a maximum of 49 PC users by means of code selection Up to 25 PC users can be called in parallel with a call button from the door station Every PC user to which a door call has been established occupies currently 2 registrations in the IPVS Remarks a Door release 12 V AC use at least 20 Ohm e g TÖ 615 b The NG 600 0 can also tak...

Страница 22: ...22 5 Installation DCIP 600 system free up to 49 users ...

Страница 23: ... PC users can be called in parallel with a call button from the door station Every PC user to which a door call has been established occupies currently 2 registrations in the IPVS Remarks a Door release 12 V AC use at least 20 Ohm e g TÖ 615 b The NG 600 0 can also take over the power supply to existing on site call buttons A voltage of 12 V AC max 200 mA is available for the lighting if a door re...

Страница 24: ...24 5 Installation DCIP 600 system free with COM 611 ...

Страница 25: ...m the door station Every PC user to which a door call has been established occupies currently 2 registrations in the IPVS Remarks a Door release 12 V AC use at least 20 Ohm e g TÖ 615 b The NG 600 0 can also take over the power supply to existing on site call buttons A voltage of 12 V AC max 200 mA is available for the lighting if a door release with an impedance of at least 20 Ohm is used With a ...

Страница 26: ...26 5 Installation DCIP 600 system free with COM 611 and AEM 645 ...

Страница 27: ...m the door station Every PC user to which a door call has been established occupies currently 2 registrations in the IPVS Remarks a Door release 12 V AC use at least 20 Ohm e g TÖ 615 b The NG 600 0 can also take over the power supply to existing on site call buttons A voltage of 12 V AC max 200 mA is available for the lighting if a door release with an impedance of at least 20 Ohm is used With a ...

Страница 28: ...28 5 Installation DCIP 600 system free with DRM 611 ...

Страница 29: ...eans of code selection Up to 25 PC users can be called in parallel with a call button from the door station Every PC user to which a door call has been established occupies currently 2 registrations in the IPVS Remarks a Door release 12 V AC use at least 20 Ohm e g TÖ 615 b The NG 600 0 can also take over the power supply to existing on site call buttons A voltage of 12 V AC max 200 mA is availabl...

Страница 30: ...d PC user 6 Commissioning DCIP 600 system free Step 1 Issue of the IP address and subnet mask in the IPVS 600 The connection can be established using a crossover network cable The IPVS 600 can also be addressed via the network if the PC and IPVS 600 are located in the same address area Start the Internet Explorer on the PC and enter the following in the address line http 192 168 0 1 The IP setting...

Страница 31: ...eparately in each IPVS 600 Multicast address video 1 For each IPVS 600 enter a multicast address which you wish to operate in the multicast mode duplication of the data streams in the network With the setting 0 0 0 0 the IPVS 600 works in the multi unicast mode copying the data streams in the device The IPVS 600 supports multi unicast connections for up to five recipients connected simultaneously ...

Страница 32: ...guration software PC with Intel Pentium III from 1 GHz or comparable processor at least 256 MB RAM min 25 MB hard disk memory Serial COM interface RS232 or serial USB adapter CD ROM drive for installation VGA graphic card with at least 1024 x 768 pixel Operating system Windows 2000 XP Admin rights for installation Additional memory capacity is required for Acrobat Reader 7 Microsoft Internet Explo...

Страница 33: ...ts E1 E4 if these are used Write the configuration to the SIVS with Send configuration In the menu File DCIP generate the SC file for later import into the Software Client If required users can be deselected which do not receive a call Note This step is intended to create different configurations for different Software Clients e g one workstation has access to doors for which another workstation i...

Страница 34: ...ewer Microsoft Internet Explorer from Version 4 0 to read the help Procedure for installation Install the DCIP SC 600 software It may be necessary to install additional programs such as Microsoft Direct X Version 9 0b Start the Software Client The Software Client configuration can be opened by pressing the right hand mouse button on the virtual in house telephone In the first tab Configuration sel...

Страница 35: ...off If there is an active firewall the application file DCIP SC 600 0 exe must be defined as an exception or as a permanently authorized program application In order to establish a video link it may be necessary for the drivers for the used graphic card to be updated to the latest status Other settings in the Software Client Free buttons Selection of functions for buttons 1 3 Each button can be as...

Страница 36: ...he door station in the direction of the PC user At the back of the TLM LL 611 set the microphone potentiometer to the middle setting as delivered status Establish the connection to the PC At the PC select Reproduction in the Speech volume menu Ensure that Tone off has been selected under the heading Microphone Using buttons and set the optimum volume starting from 0 To ensure that the levels are s...

Страница 37: ...37 ...

Страница 38: ...is function can be switched off If the number 61 is pressed the door release is actuated for 3 seconds For connection of more than one telephone a so called group call or collective call function must be set up in the telephone system For details ask the telephone system installer Power supply The DCA 740 is supplied directly from the SIVS 600 A separate supply is consequently not required The pow...

Страница 39: ...This problem occurs primarily with laptops Check in the BIOS whether the memory assignment can be set for the graphics card If so set this to 32 MB this problem occurs primarily with laptops Set the hardware acceleration of the graphics card display to max Speech goes from the PC only in the direction of the door Enter the software DCIP SC 600 0 exe in the Windows firewall as an exception Ensure t...

Страница 40: ...t line rectifier NG 600 12 V AC Voltage b c at SIVS 600 15 V DC Voltage Da Db at SIVS 600 0 3 V DC Call status Voltage E1 E4 G at SIVS 600 20 V DC 30 V DC voltage USP at SIVS 600 20 V DC 30 V DC Sprechbetrieb Speech mode Voltage M at CMC 612 20 V DC 30 V DC Voltage Mu M at TLM LL 611 and CMC 612 20 V DC 30 V DC DCIP mit DCA 740 DCIP with DCA 740 analogue PBX extension La Lb 20 V DC 60 V DC ...

Страница 41: ...titute grounds for any claims to damages Connection 18 As delivered status 38 Block diagram 16 Client 6 34 Commissioning 30 Config 30 Cross over 30 DoorCom 10 Factory setting 38 Full duplex 6 HTTP 6 IP 6 IP address 6 IWA 7 LAN 7 LED display 15 Licences 11 34 Line rectifier 10 Multicasting 7 31 Network cable 30 Power supply 4 10 Programming 30 Push to talk 7 Reset 38 RS232 7 RS485 7 Server 7 Softwa...

Страница 42: ... 2007 02 09 Printed in Germany Order no 0 1101 037154 EN S Siedle Söhne Postfach 1155 D 78113 Furtwangen Bregstraße 1 D 78120 Furtwangen Tel 49 7723 63 0 Fax 49 7723 63 300 www siedle de info siedle de ...