INSTRUCTION SHEET
OPT-1 OPTICAL FIBER PULSE TRANSMITTER (con't)
Fiber Optic Cable Connections -
Locate the two "ST" fiber optic ports on the OPT-1's media convertor
module. Connect the fiber optic cable to these ports using the twist lock connections. The cables should be
"crossed" such that each cable is connected to the "T" fiber optic port on one end and the "R" fiber optic port
on the other end.
The OPT-1 will transmit pulse information to the OPR-1 Optical Fiber Pulse Receiver up to approximately
5000 meters or about 3 miles using multimode fiber. Care should be taken to follow all proper fiber optical
cable implementation standards.
SOLID STATE INSTRUMENTS
a division of Brayden Automation Corp.
6230 Aviation Circle, Loveland Colorado 80538
Phone: (970)461-9600 Fax: (970)461-9605
E-mail: [email protected]
OPT-1
Optical Pulse
Transmitter
K
Z
Y
K1
Z1
Y1
Output
Tx
3 Miles Max w/ MM
Optical Fiber
Cables
KYZ
Pulse
Input
Tx
Rx
Rx
27
7V
12
0V
N
EU
G
ND
OPR-1
Optical Pulse
Receiver
Power
Supply
Connections
N/C
27
7V
12
0V
N
EU
G
ND
N/C
Power
Supply
Connections
From
Electric
Meter
OPL SYSTEM BLOCK DIAGRAM