![SSI Fluid-Trac DFT-110 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/ssi/fluid-trac-dft-110/fluid-trac-dft-110_product-overview_1354551004.webp)
ssi-sensors.com
4
Copyright © 2019, SSI Technologies, LLC
Doc. DT-AN5 — Rev. 01
Mounting
Digital Fluid-Trac
®
works well on ANSI MH2 standard 55 gallon drums as it mates with closedhead
standardized bunghole arrangements. The 55 gallon drum gauge mounts on top of the drum with a
standard 2” NPT thread connector. A ¾ inch NPS threaded adapter is included with each
Digital FluidTrac
®
Model DFT-110 so either bung opening can be used on the drums.
When using the Digital Fluid-Trac
®
, it is important to keep the mounting perpendicular to the liquid level
by storing the drums in an upright position.
Material Specifications
Incorrect
Correct
Electrical Specifications
* Battery Life will vary dependant on operator’s usage.
Battery specification is based on two level readings per day.
** Outside of stated dead band
Resolution (Gallons) **
0.5 gallons
Resolution (Liters) **
1 Liter
Operating Temperature
0 °C to 50 °C
Battery Life *
6 months alkaline, 1 year lithium
Low Level Warning Activation (Red LED)
≤ 10% Max Volume
Low Battery Level (Lob)
≤ 14.2 Volts Combined
Description
Material
Display housing / threaded adaptor (blue plastic)
PBT (Polybutylene terephthalate), 15% glass filled
Transducer housing (black plastic inside threaded adaptor)
HDPE (High Density Polyethylene)