SSI Fluid-Trac DFT-110 Скачать руководство пользователя страница 4

ssi-sensors.com

4

Copyright © 2019, SSI Technologies, LLC

Doc. DT-AN5  —  Rev. 01

Mounting 

Digital Fluid-Trac

®

 works well on ANSI MH2 standard 55 gallon drums as it mates with closedhead 

standardized bunghole arrangements. The 55 gallon drum gauge mounts on top of the drum with a 

standard 2” NPT thread connector. A ¾ inch NPS threaded adapter is included with each 

Digital FluidTrac

®

 Model DFT-110 so either bung opening can be used on the drums.

When using the Digital Fluid-Trac

®

, it is important to keep the mounting perpendicular to the liquid level 

by storing the drums in an upright position.

Material Specifications 

Incorrect

Correct

Electrical Specifications 

 

* Battery Life will vary dependant on operator’s usage. 

Battery specification is based on two level readings per day.

** Outside of stated dead band

Resolution (Gallons) **

0.5 gallons

Resolution (Liters) **

1 Liter

Operating Temperature

0 °C to 50 °C

Battery Life *

6 months alkaline, 1 year lithium

Low Level Warning Activation (Red LED)

≤ 10% Max Volume

Low Battery Level (Lob)

≤ 14.2 Volts Combined

Description

Material

Display housing / threaded adaptor (blue plastic)

PBT (Polybutylene terephthalate), 15% glass filled

Transducer housing (black plastic inside threaded adaptor)

HDPE (High Density Polyethylene)

Отзывы: