Safety Precautions

 

This device is a precision electrical instrument. For the sake of safety, be sure to follow the 

instructions described in this manual. 

  mark are precautions that must be followed in order 

to use the product safely. 

This device does not conform to explosion-proof specifications. Do not install it 
in locations where flammable gases or solvents are handled, such as painting 
booths etc. Doing so may result in fire or explosion.   

This device is a precision electrical instrument. Avoid installing it in wet, oily, 
hot, and humid locations. In particular, avoid locations of high humidity and 
condensation. There is a possibility of fire due to breakdown.

   

 

  Installation   

 

Do not use this device in the following locations, as doing so may cause malfunctions.

 Locations subject to high or low 

temperature, or high humidity 

 Dusty locations 

 Locations where the device may be 

exposed to organic solvents such as 
thinner 

 Locations where the device may be 

exposed to corrosive gas 

 Locations subject to flames or 

explosions 

 Locations subject to frequent vibrations 

 Locations subject to sudden changes in 

temperature or humidity 

 Locations subject to condensation 

 Locations where the device may be 

exposed to water or oil

 

  Maintenance   

  Regularly  remove  any  built-up  dirt  etc.  from  the  optional  ion  balance  plate.  Built-up  dirt  can 

cause insulation faults. 

  Make sure to turn the main power of the device OFF before cleaning. 

 

  Handling   

  Make sure to connect the earth wire to an appropriate place. Accurate measurements are not 

possible if the earth wire is not connected. 

  To  obtain  accurate  measurements,  measure  at  an  appropriate  distance  from  the  charged 

object. 

  Do not touch or insert foreign materials into the sensor portion of this device. 

  Do not blow ionized air directly into the opening of this device. 

  Do not place heavy objects on the LCD display of this device. 

  Do not disassemble or modify the device. 

  The device may affect medical devices such as hearing aids or pacemakers. 

  Do  not  insert  any  foreign  objects  into  the  device.  Doing  so  may  result  in  a  short  circuit  or 

current leakage, and cause fire or electrocution. 

  The battery discharges a small amount of electricity even when the device is turned off. If you 

do not intend to use this device for an extended length of time, remove the battery. 

  If the device emits any abnormal odors or sounds, smoke, or heat, turn OFF the main power 

immediately, and contact your point of purchase. Failure to do so may result in fire or a short 
circuit. 

  Do not remove name plates or labels. 

  Do not do anything with the device that is not described in this manual.

 

Содержание Statiron DZ4

Страница 1: ...lectrical potential meter with digital readout for measuring the electrical potential of charged objects When measuring fluctuating static electricity you can temporarily hold an indicated value and c...

Страница 2: ...osed to water or oil Maintenance Regularly remove any built up dirt etc from the optional ion balance plate Built up dirt can cause insulation faults Make sure to turn the main power of the device OFF...

Страница 3: ...using it for the first time Instruction manual warranty x 1 this document Main Device Earth Lead x 1 Strap x 1 Battery 006P type 9V alkaline dry cell battery x 1 Soft case Model number ODZ4 SFTCS x 1...

Страница 4: ...al changes according to the field strength concentrated in the electrode of the sensor portion of the meter and the size of the charged object In particular if the charged object is smaller than the t...

Страница 5: ...ad to a grounded object To obtain accurate measurements the earth terminal must be grounded Measurement Procedure Measuring Static Electricity 1 Turn the meter on Press the POWER button for more than...

Страница 6: ...re 3 Fig 3 Red LED mark NOTE If the recommended measuring distance of 30mm cannot be attained do not bring the meter any closer if the potential displayed exceeds 19 99kV Doing so may cause damage to...

Страница 7: ...e the I B mode 3 Zero point adjust the meter Point the sensor at a grounded object and press the 0ADJ button NOTE Zero point adjustment is reset when you turn the meter off 4 Attach the ion balance pl...

Страница 8: ...s occurs stop measuring immediately as this may cause damage to the meter 7 The value on the display panel is the measurement result unit kV 8 In I B mode you can temporarily hold the measured value b...

Страница 9: ...ed on the upper right of the display panel When the battery charge icon shows one unit left replace the battery Error Display The signal detection method of the meter is an oscillating chopper method...

Страница 10: ...correct Remedy 1 Perform zero point adjustment again Cause 2 Structural components close to the sensor are charged Remedy 2 Wait until the charge in the components has attenuated The display does not...

Страница 11: ...measured and sensor Measuring distance adjustment Red LED beam focusing method Sensor head rotation angle 180 stops every 45 Display LCD display with built in backlight Polarity display polarity pola...

Страница 12: ...where you purchased the product SHISHIDO ELECTROSTATIC LTD http www shishido esd co jp HEAD OFFICE MARUNOUCHI BLDG 9F 918 4 1 MARUNOUCHI 2 CHOME CHIYODA KU TOKYO 100 6309 SALES DEPARTMENT TOKYO BRANCH...

Отзывы: