ADVANCED CONTROLLER SETTINGS
(CONTINUED)
HYSTERESIS SETTINGS
TEMPERATURE CALIBRATION SETTINGS
The “Hd” and “Cd” are menus which adjust by 0.1 degrees to offset heating and cooling from a set
point. “Hd” being heating degrees from the set point to kick on and “Cd” being cooling from your current
set temp to kick on.
Press “Set” key and hold more than 3 seconds to enter the menu display, with “
” or “
” key adjusted
to the screen, appearing “Hd” or “Cd” code, press the “Set” key to display the hysteresis set value,
press “
” or “
” key to adjust the parameters. Factory Default = “1°”.
Press “Set” key and hold more than 3 seconds to enter the menu display, with “
” or “
” key adjusted
to the screen, appearing “CA” code, press the “Set” key to display the temperature calibration settings,
press “
” or “
” key to adjust the parameters. Factory Default = “0”.
Set
Rst
SET
Set
Rst
SET
Set
Rst
SET