( 3 / 4)
Front panel:
Rear panel:
Device in use / service:
By default, Power LED indicates the device is on main power. When the Power
LED is off, check the main power input. When this does not solve the problem,
please call service first and then open DST5-RDM and check fuses on the main
board.
When the DMX cable is connected to the device, LEDs marked as D+ and D- go
on for the side marked as DMX input, thru and this indicates that DST5-RDM is
receiving the DMX signal. Speed of light on these LEDs also indicates the
refresh rate of DMX signal. Fast blinking – high refresh rate, slow blinking – slow
refresh rate.
On the front panel of DST5-RDM, there are outputs A-E, which are retransmitting
the input to the optically isolated outputs. If any of data LEDs is off, unplug the
signal cable corresponding to this output and check the cable for short circuit
between D+ and CMN or D- and CMD lines.
RDM filter switch will filter all RDM commands from the DMX stream.
In case of any problems, do not hesitate to contact us via email at
or call us at +421244681417. Don’t worry; we will fix your
problems for sure.