IMPORTANT SAFETY INFORMATION 

 
The following general safety precautions have to be observed during all phases 
of  operation,  service,  and  the  repair  of  this  equipment.  Failure  to  comply  with 
these  precautions  or  with  specific  warnings  in  this  manual  violates  safety 
standards of design, manufacture, and the intended use of this equipment. 
 

Do not operate in an explosive atmosphere! 

 
Do  not  operate  this  equipment  in  the  presence  of  flammable  gases  or  fumes. 
Operation  of  any  electrical  instrument  in  such  an  environment  constitutes 
a definite  safety  hazard.  Device  should  be  never  placed  near  or  over  a  heat 
register or other source of heated air and it should not be installed or operated 
without  proper  ventilation.  Due  to  the  IP65  sealing,    the  device  should  be 
installed in constant temperature atmosphere without thermal shocks. 

 
Mains 85-265V connection 

 

AC screw terminal is located near the PSU. Please follow the marking of L and N 
on the PCB for correct wiring of Line and Neutral.  
 

DMX connection 

 

DMX  screw  terminal  connectors  are  located  on  both  sides  of  board.  These  are 
separated into two groups. One group is wired in ratio 1:1 and marked as > and >. 
This  line  should  be  terminated  by  the  termination  resistor  of  120ohm  wired 
between pins 2 and 3 or D+/D- signal when the device is last on DMX line. 
 
The other part of splitter consists of 10-way optically isolated lines marked with 
letters  A-J.  Each  line  has  a  separate  power  supply  and  line  driver  +  the 
indication of signals D+, D- on the both signal lines with two LEDs marked as D+, 
D-. In normal operation, both LEDs are on. In case of short circuit between data 
pins D+/D- and the CMN pin, the LED with short circuit is OFF. These LEDs also 
indicate the refresh rate of DMX signal. 

 

 

All outputs are optically isolated! 
 

Pin 1   

Data Common 

Pin 2   

Data- / D- 

Pin 3   

Data+ /D+ 

 
 
 

Содержание DSR10IP

Страница 1: ...s important information about the installation and the use of the equipment Please read and follow these instructions carefully Always ensure that the power to the equipment is disconnected before opening the equipment or commencing any maintenance work DSR10IP_en_manual_M067 10 way IP DMX Splitter DSR10IP ...

Страница 2: ...phere without thermal shocks Mains 85 265V connection AC screw terminal is located near the PSU Please follow the marking of L and N on the PCB for correct wiring of Line and Neutral DMX connection DMX screw terminal connectors are located on both sides of board These are separated into two groups One group is wired in ratio 1 1 and marked as and This line should be terminated by the termination r...

Страница 3: ...P is receiving the DMX signal Speed of light on these LEDs also indicates the refresh rate of DMX signal Fast blinking high refresh rate slow blinking slow refresh rate Now the DSR10IP is fully working and retransmitting the input to the optically isolated outputs If any of data LEDs is off unplug the signal cable corresponding to this output and check the cable for short circuit between D and CMN...

Страница 4: ...a 38 B SK 83108 Bratislava Slovak Republic Declares that the product Name of product 10 way waterproof DMX splitter Type DSR10IP Corresponds to the following product specifications Safety EN60065 resp EN 60950 EMC EN55103 1 resp EN55103 2 Bratislava 10 May 2011 Robert Sloboda Copyright 2017 SRS Group s r o Specifications subject to change without notice Document DSR10IP_en_manual_M067 Version 1 0 ...

Отзывы: