background image

 

( 3 / 4) 

Controls and indication 

 

 

 

1.

 

DMX input signalization 

2.

 

DMX input/output connectors 

3.

 

Termination switch 

4.

 

DMX output signalization 

5.

 

DMX output connector 

 
Device Design 

 

Front panel: 

 

 

Rear panel: 

 

 

Device use / servicing: 

 
The ON LED indicator indicates the device is on the main power. All other data 
indication  LEDs  being  off  mean  no  incoming  signal.  The  termination  LED  is  on 
when the termination switch is activated. 
 
When the DMX cable is connected to the device, all LEDs marked as 2 / 3 or the 
sign  of  signal  polarity  go  on.  This  indicates  that  DSR10  is  functioning  properly 
and  is  retransmitting  the  input  to  the  outputs.  If  any  of  LEDs  is  off,  check  the 
cable first – short circuit on a line causes the respective LED is off. 
 
If  case  of  any  problems,  do  not  hesitate  to  contact  us  via  email  at 

rma@srs-

group.com

  or  call  us  at  +421244681417.  Don’t  worry;  we  will  fix  your  problems 

for  sure.  Keep  in  mind  that  your  device  has  a  life-time  warranty  and  you  will 
receive a free replacement. 

Содержание DSR10-3

Страница 1: ...tant information about the installation and the use of the equipment Please read and follow these instructions carefully Always ensure that the power to the equipment is disconnected before opening the equipment or commencing any maintenance work DSR10_en_manual_M061 10 way DMX Splitter DSR10 3 DSR10 5 DSR10 C ...

Страница 2: ...midity atmosphere where condensation forms on the equipment It should never be placed near or over a heat register or other source of heated air and it should not be installed or operated without proper ventilation DMX connections DMX 3 or 5 pin XLR connectors are located on the front panel of the device They are separated into two groups A group on the left is wired in ratio 1 1 and marked as DMX...

Страница 3: ...nation switch is activated When the DMX cable is connected to the device all LEDs marked as 2 3 or the sign of signal polarity go on This indicates that DSR10 is functioning properly and is retransmitting the input to the outputs If any of LEDs is off check the cable first short circuit on a line causes the respective LED is off If case of any problems do not hesitate to contact us via email at rm...

Страница 4: ...wing product specifications Safety EN60065 resp EN 60950 EMC EN55103 1 resp EN55103 2 Additional information Unit and all connected apparatuses must be earthed via main cable Bratislava 10 May 2009 Robert Sloboda Copyright 2017 SRS Group s r o Specifications subject to change without notice Document DSR10_en_manual_M061 Version 1 0 Actual as of 9 June 2017 SRS Group s r o Rybnicna 36 D 831 07 Brat...

Отзывы: