6.

 

Output wiring 

6.1

 

Remote multipin connector 

 
Amphenol DS3106A28-21P 
 

Pin 

Function 

CMC12A  CMC8A 

M1 down 

M1 up 

M2 down 

M2 up 

M3 down 

M3 up 

M4 down 

M4 up 

M5 down 

10 

M5 up 

11 

M6 down 

12 

M6 up 

13 

M7 down 

 14 

M7 up 

15 

M8 down 

16 

M8 up 

17 

M9 down 

18 

M9 up 

19 

M10 down 

20 

M10 up 

21 

M11 down 

22 

M11 up 

23 

M12 down 

24 

M12 up 

25 

Contactor ON 

26 

AC1 24V 

27 

AC1 24V 

28 

AC1 24V 

29 

AC2 24V 

30 

GROUND 

 

6.2

 

E-stop connector 

 

Unit  is  equipped  with  certified  SIL3  E-STOP  safety  relay.  For  additional  safety,  up  to  two 
sources of E-STOP can be connected. Usually one of them is the RMC unit and the other one 
should be the load cell unit. According to the requirement, both lines are normally closed – NC. 
Because  of  this,  it  is  necessary  to  fit  the  safety  breach  /MXX  connector  with  a  short  circuit 
between pins 1 and 2, and pins 3 and 4. Both lines are separated and CANNOT be connected 
together – otherwise it will not be possible to reset the safety circuit. 
 

Neutrik NC4FXX

  

Pin 1: Safety line 1 IN 

 

 

 

Pin 2: Safety line 1 OUT 

 

 

 

Pin 3: Safety line 2 IN 

 

 

 

Pin 4: Safety line 2 OUT 

 

Содержание RMC12

Страница 1: ...12 2014 ATTENTION This instruction manual contains important information about the installation and the use of the equipment Please read and follow these instructions carefully Always ensure that the...

Страница 2: ...autions or with specific warnings in this manual violates safety standards of design manufacture and the intended use of this equipment Do not operate in an explosive atmosphere Do not operate this eq...

Страница 3: ...he MCseries controller Connect Remote2 E stop connector to the MCseries controller Select type of operation LOCAL REMOTE using the KEY switch Check if the emergency STOP button is not engaged Engage t...

Страница 4: ...com sales srslight com 4 4 RMCseries base unit 4 1 RMCseries front panel 4 2 RMCseries rear panel E stop connector NC4FDL Remote A Remote B link connectors are 3 pin NC3MDL NC3FDL or NC3MAH and NC3FA...

Страница 5: ...is latching pushbutton switch turns the Hoist Control system off Once the STOP button has been pressed it is locked into the off position and must be rotated clockwise to be released 5 2 GO This pushb...

Страница 6: ...E STOP STATUS LED Green E STOP system is OK Orange Indicates that the system needs to be reset Red E STOP is active somewhere in the system RED blinking E STOP button is pressed on the device 5 7 CMC...

Страница 7: ...up S 25 Contactor ON a a 26 AC1 24V g g 27 AC1 24V n n 28 AC1 24V p p 29 AC2 24V r r 30 GROUND s s 6 2 E stop connector Unit is equipped with certified SIL3 E STOP safety relay For additional safety u...

Страница 8: ...ia network to all linked controllers RS485 is used as a communication link Neutrik NC3FXX MXX Pin 1 Data common Pin 2 Data minus Pin 3 Data plus 6 4 CMC DIGITAL connection CMC remote connectors are us...

Страница 9: ...es srslight com 9 7 Linking of RMCseries units Up to 10 RMC base units can be linked together for a group operation of GO buttons For linking of RMC base use a 3 pin XLR cable connected as 1 1 between...

Страница 10: ...ata Main Power AC208 230V 50 60Hz T2 5 Optional AC110V 60Hz 8 1 Protections and Safety Dry contacts all outputs are galvanic isolated Double Recessed Emergency stop SIL3 safety module Double encoded d...

Страница 11: ...rs the original factory installed components of the controller and their correct functioning Warranty voids if any part or replacement components are installed or modified without authorization from t...

Страница 12: ...ybnicna 36 D SK 83106 Bratislava Slovak Republic www srslight com sales srslight com 421244681417 Declares that the product Name of product RMCseries hoist controller RMC8 RMC12 and variants Types RMC...

Страница 13: ...panel 4 4 5 Optional CMC DIGITAL remote 5 5 5 1 STOP 5 5 5 2 GO 5 5 5 3 DIRECTION SWITCHES 5 5 5 4 DIRECTION SWITCH LED 5 6 5 5 STATUS LED 5 6 5 6 E STOP STATUS LED 5 6 5 7 CMC DIGITAL Remote connecto...

Отзывы: