![Srne HF4830S60-H Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/srne/hf4830s60-h/hf4830s60-h_product-manual_1354150022.webp)
photovoltaic charge can be started.
[06] OSO
Only photovoltaic charge, no AC charge is started.
07
Maximum
Charge current
[07] 60A
default
Setting range 0~80A;
08
Battery type
[08] USE
For user-defined, all battery parameters can be
set.
[08] SLd
Sealed lead-acid battery, constant voltage
charge voltage 57.6V, float charge voltage 55.2V.
[08] FLd
For vented lead-acid battery, charge voltage
at constant voltage is 58.4V and float charge
voltage is 55.2V
[08] GEL
default
For gel lead-acid battery, charge voltage at
constant voltage is 56.8V and float charge
voltage is 55.2V.
[08] L14/L15/L16
Lithium iron phosphate battery L14/L15/L16
corresponds to lithium iron phosphate battery
14 strings/15 strings/16 strings;16 string/15
string/14 string default constant
The voltage charging pressure is 56.8V, 53.2V,
49.6V, which are adjustable.
[08] N13/N14
Ternary lithium battery; which is adjustable.
09
Boost charge
voltage
[09] 57.6V
default
The setting range of boost charge voltage is
48V~58.4V with 0.4V step. It is valid in case of
a self-defined or a lithium battery.
10
Boost charge
maximum
time
[10] 120
default
Boost maximum charge time setting means
setting of maximum charge time of voltage
when the voltage reaches parameter
【
09
】
from 5min~900min at 5-minute step. It is valid
in case of a self-defined or a lithium battery.
11
Float voltage
[11] 55.2V
default
48V~58.4V setting range of float voltage at
0.4V step is valid in case of a self-defined battery.
12
Overdischarge
voltage
[12] 42V
default
So as to overdischarge voltage, when the
battery voltage is lower than the judgement
point, after delaying for the parameter
【
13
】
setting time, turn off the inverter output.
40V~48V voltage setting range at 0.4V step is
valid in case of a self-defined battery and
lithium battery.
Solar Energy Storage Inverting & Control All-In-One Machine 22