SR Scales SR735i Скачать руководство пользователя страница 19

Model SR735

i

 Wheelchair Scale 

Operating and Service Manual  
Part No. MAN735

i

 _MICROBAN_201210 

 

Page 19 of 20 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

       Copyright 2020

 

S

Instruments, Inc. 

NOTES 

Содержание SR735i

Страница 1: ..._MICROBAN_201210 Page 1 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S...

Страница 2: ...USE 6 MICROBAN ANTIMICROBIAL PROTECTION 6 STORAGE 6 CLEANING AND DISINFECTING 7 SPECIFICATIONS 8 BUTTON FUNCTIONS 9 BASIC SYSTEM OPERATION 11 BATTERY REPLACEMENT 12 THEORY OF OPERATION 13 CALIBRATION...

Страница 3: ...wanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc PACKING CHECKLIST SR735i Platform Scale DESCRIPTION QUANTITY Box 1 WHE...

Страница 4: ...lease call the service hotline at 1 800 654 6360 STEP 2 Verify that the serial number on the Display Unit matches that on the Wheelchair Scale Assembly STEP 3 The SR735i Display may be wall mounted Fi...

Страница 5: ...ing Bracket Figure 4 Use the wall mounting hardware provided for installing the bracket STEP 2 Carefully attach the printer to the Printer Mounting Bracket Connect the printer cable from the printer t...

Страница 6: ...be viewed either in pounds or kilograms with a displayed resolution of 0 1 for each INTENDED USE The SR735i Wheelchair Scale System is specifically designed for weighing both motorized wheelchair and...

Страница 7: ...eas Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disin...

Страница 8: ...e AUTO ZERO One button operation AUTO POWER DOWN Approximately 30 seconds adjustable to 300 seconds RECALL Recalls last stored stable weight height and BMI AVERAGING Automatic digital filter POWER SUP...

Страница 9: ...when stable Auto stores stable weight in memory SEND PRINTER EHR Press to send stored values to EHR or to printer Output values include time date weight height and BMI Also indicated on display when...

Страница 10: ...ON TIME Use UP or DOWN arrow buttons to adjust the ON TIME The ON TIME may be set from 30 to 300 seconds in 30 second increments Press ENTER to save changes Setting TIME and DATE Use the UP arrow butt...

Страница 11: ...When the weight is stable the weight stable indicator remains solid The display will indicate the patient s weight in either pounds or kilograms example WT 123 5 Lb The stable weight is auto stored i...

Страница 12: ...example RCL WT 123 5 Lb RCL HT 65 in and RCL BMI 20 5 BATTERY REPLACEMENT STEP 1 The display will read REPLACE BATTERY STEP 2 Figure 7 Unscrew the panel screw on the Battery Compartment Cover and remo...

Страница 13: ...plifier is configured to current sum the output of each cell with potentiometers serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiometer pro...

Страница 14: ...subset of weight that is less than half of the combined weight DO NOT USE barbells or uncalibrated weights STEP 2 Zero the scale by pressing and holding ZERO WEIGH button STEP 3 Place the subset of c...

Страница 15: ...weight of the calibrated weights Use the UP arrow button to select the digit and the DOWN arrow button to change digit Press ENTER to save changes STEP 4 Press the MENU button until HALF 500 00 Lb is...

Страница 16: ...EP 5 Switch the scale system out of the Calibration Mode on the display board Figure 9 STEP 6 Place the left end cover on the display housing Attach using three 3 cover screws EHR OUTPUT Electronic Me...

Страница 17: ...ry Wait five seconds then re install the battery and try the WEIGH button again The display lights appear to work but do not respond to button activation Check to ensure the membrane switch label is c...

Страница 18: ...abilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no...

Страница 19: ...and Service Manual Part No MAN735i _MICROBAN_201210 Page 19 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments co...

Страница 20: ...AN735i _MICROBAN_201210 Page 20 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstrument...