ASSEMBLY 

 

 

STEP 1

:  Unpack  the  scale  system  and  check  parts 

against  the 

PACKING  CHECKLIST

.    If  there  are 

any missing or damaged parts, please call the Service 
Hotline at:  1-800-654-6360. 

STEP 2

:  Verify that the serial number on the label of 

Wall Box Display matches that on Platform Base.  

STEP  3

:  (Figure  1)  Mount  Wall  Box  Display  into 

wall and run the conduit, with connector cable inside, 
down through wall and into pit as shown.  

STEP 4

:  Prepare  pit  area  to  accept  the  Scale 

Frame.    It  is  recommended  that  a  properly 
plumbed  drain  be  installed  in  the  center  of  pit  to 
avoid any water buildup that might damage scale. 

STEP 5

:  Center the Scale Frame in the pit.  

NOTE:

  Scale  frame  dimensions  are  52”  x  28”  x  2”  deep.    Recommended  pit  perimeter 

dimensions are 58” x 34”.  

STEP 6

(Figure 2) Back fill around the perimeter of the Pit Frame Assembly with 3000PSI concrete.  

Trowel the concrete level with the scale frame and existing floor.  Trowel the base of the pit level with 
the base of the frame with a gradient toward the centered drain, if used.  Conduit and cable should be left 
free so cable can be easily connected to the Platform Assembly. 

 

STEP 7

When the concrete has set, connect the Cable Assembly to 

the mating connector on the Platform Assembly. 

STEP 8

Carefully  lower  the  Platform  Assembly  into  the  Pit  Frame 

Assembly.  Ensure that Platform feet set into locators on Pit Frame and that 
extra cable does not interfere with platform. 

 

STEP 9:

  Install  building  ground  wire  and  green ground wire from  Display  Front Plate  into the 

terminal lug in the wall box 

STEP 10: 

Connect signal cable to the mating connector on the Display Front Panel 

STEP 11:

  Connect A/C power wires to the power supply wire leads 

STEP 12:

  Install Front Panel Assembly to the previously  mounted Wall Box.  Use supplied star 

washers and screws.  Ensure screws are securely tightened. 

STEP 13:

  Restore power to the display

 

Figure 1:  Wall Box Assembly/Conduit 

Placement 

Figure 2:  Concrete Fill

 

Содержание SRScales SRV947IFS

Страница 1: ..._190708 Page 1 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2019 SInstruments Inc SRV947IFS B...

Страница 2: ...ENTS TABLE OF FIGURES 2 PACKING CHECKLIST MODEL SRV947IFS BT 3 ASSEMBLY 4 REPLACEMENT PARTS AND ACCESSORIES 5 SYSTEM DESCRIPTION AND INTENDED USE 5 MAINTENANCE AND CLEANING 6 STORAGE AND TRANSPORTATIO...

Страница 3: ...14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2019 SInstruments Inc PACKING CHECKLIST Model SRV947IFS BT Portable Platform Scale DESCRIPTION QUANT...

Страница 4: ...eter dimensions are 58 x 34 STEP 6 Figure 2 Back fill around the perimeter of the Pit Frame Assembly with 3000PSI concrete Trowel the concrete level with the scale frame and existing floor Trowel the...

Страница 5: ...an accurate representation of the animal s weight The animal s weight is displayed on an LCD screen With a push of a button weight data may be viewed in either pounds or kilograms The SRV947IFS BT Pla...

Страница 6: ...e cleaners Mild soap and water is recommended for general cleaning and disinfecting STORAGE and TRANSPORTATION STORAGE To maintain proper operation of this instrument storage and transport conditions...

Страница 7: ...ts of displayed resolution for calibrated range AUTO ZERO One button operation Hold for Zero AVERAGING Automatic digital filter POWER SUPPLY 110v AC 50 60Hz CALIBRATION Calibration is traceable to NIS...

Страница 8: ...instruments com Copyright 2019 SInstruments Inc MODE ZERO HOLD RECAL L BUTTON FUNCTIONS The ZERO WEIGH button is used to clear the Recall memory and start a new weighing cycle Press and hold for 3 sec...

Страница 9: ...lay 0 0 when system is ready for weighing UNIT Press the MODE button to toggle between pounds or kilograms The system will remain in the same mode as last used unless manually changed WEIGH The WEIGH...

Страница 10: ...the Android device by pressing the Bluetooth icon in the application and then pressing Scan for devices 3 Locate the scale Bluetooth module in the list of devices The scale s Bluetooth ID is listed on...

Страница 11: ...OM REASON CORRECTIVE ACTION Display reads LOW Ensure scale is on a level surface Check to make sure all six feet are touching ground and ensure that nothing is touching bottom or sides of platform For...

Страница 12: ...nstruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR In...

Страница 13: ...Scale Operating and Service Manual Part No MAN947IFSBT_190708 Page 13 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srins...

Страница 14: ...Manual Part No MAN947IFSBT_190708 Page 14 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2019...