CLEANING and DISINFECTING 

 

CLEANING 

To clean the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with water and mild detergent to clean scale surfaces. 

 

Wipe surface with clean soft cloth dampened with water and then dry with clean soft cloth.  

 

Do  not  use  abrasive  materials  to  clean  scale  surface  to  prevent  damage  to  the  surface 
finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth. 

 

DISINFECTION 

To disinfect the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth.  Cloth 
cannot  be  dripping  wet.    Follow  manufacturer’s  instruction  on  the  proper  use  of 
commercially available disinfectants.  

 

Disinfectant solutions with 1% sodium hypochlorite or 70% isopropyl alcohol are suitable 
for display / user interface and other scale contact surfaces. 

 

After  disinfecting,  use  a  soft  cloth  dampened  with  clean  water  and  dry  with  a  soft  clean 
cloth to prevent buildup of material on scale finish. 

 

Do  not  use  abrasive  material  to  disinfect  /  clean  scale  surfaces  to  prevent  damage  to  the 
surface finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth.  

 

WARNING:

 

DO  NOT  SPRAY  CLEANING  SOLUTION  OR  LIQUIDS  DIRECTLY 
ON SURFACES TO BE CLEANED

 

WARNING:  EXPOSURE  TO  EXCESSIVE  LIQUID  WILL  DAMAGE  USER 

INTERFACE KEYPAD. 

 

WARNING:

 

DO  NOT 

USE  PRESSURIZED  WATER  OR  STEAM.  THE  SCALE 

SYSTEM CONTAINS ELECTRONIC COMPONENTS THAT MAY BE 

ADVERSELY  AFFECTED  BY  EXPOSURE  TO  SUCH  AN 

ENVIRONMENT. 

Содержание SRScales SRV716W Series

Страница 1: ...f 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc S by SR Instruments Inc Ope...

Страница 2: ...EL SRV716W 3 ASSEMBLY 4 REPLACEMENT PARTS AND ACCESSORIES 4 SYSTEM DESCRIPTION AND INTENDED USE 5 STORAGE AND TRANSPORTATION 5 CLEANING AND DISINFECTING 6 SPECIFICATIONS 7 BUTTON FUNCTIONS 8 BASIC SYS...

Страница 3: ...Y 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc PACKING CHECKLIST Model SRV716W Marine Platform Scale DESCRIPTION QUANTITY PL...

Страница 4: ...any missing or damaged parts call the Service Hotline at 1 800 654 6360 STEP 2 Place the Platform upside down on the floor and remove the cover on the Battery Compartment STEP 3 Install six 6 AA cell...

Страница 5: ...d with a displayed resolution of 0 2 pounds or 0 1 kilograms The SRV716W Marine Platform Scale is equipped with a Bluetooth wireless module By waking the scale up with the weigh button the wireless fe...

Страница 6: ...soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disinfectants...

Страница 7: ...LUETOOTH ON TIME 5 minutes from last button press AVERAGING Automatic digital filter POWER SUPPLY Six 6 AA cell batteries CALIBRATION Calibration is traceable to NIST standards OPERATING CONDITIONS No...

Страница 8: ...side of the scale Select the mode for weighing with this Toggle Button BASIC SYSTEM OPERATION Ensure that the scale is free and clear of any obstructions before operating Press the DISPLAY button and...

Страница 9: ...less operation Use your Android device to display weight and control the SRV716W scale functions Figure 3 Ensure your remote display indicates CONNECTED before use The WEIGH button will display weight...

Страница 10: ...acement is needed an indicator will appear on the display STEP 1 Turn the platform over and remove the four screws on the Battery Cover Figure 4 STEP 2 Remove and replace the six 6 AA cell batteries S...

Страница 11: ...four strain gauges mounted in a full Wheatstone bridge configuration These bridges convert the physical movement of the force cell due to the applied mass on the system into minute changes in electric...

Страница 12: ...weight from Step 1 Use the DISPLAY button to select digit positions and use button S4 to change the value STEP 7 When finished the display will read SAVE Press the DISPLAY button to save or press butt...

Страница 13: ...curely tighten screws NOTE TIGHTEN SCREWS ONLY UNTIL RUBBER SEAL STARTS TO COMPRESS STEP 14 Press and hold the DISPLAY button to zero the platform When the display indicates 0 0 place the calibrated w...

Страница 14: ...s on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event sh...

Страница 15: ...and Service Manual Part No MAN716W_210528 Page 15 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyrig...

Страница 16: ...AN716W_210528 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc S By...

Отзывы: