SAFETY INSTRUCTIONS 

 

 

This device has left the factory in perfect condition. In order to maintain this condition and 
to ensure a safe operation, it is absolutely necessary for the user to follow the safety

 

instructions and warning notes written in this user manual. 

 

 

 

 

 

If the device has been exposed to temperature changes due to environmental changes, do 
not switch it on immediately. The arising condensation could damage the device. 

Leave the device switched off until it has reached room temperature. 

This device falls under protection-class I. Therefore it is essential that the device be 
earthed. 

The electric connection must carry out by qualified person. The device shall only be used 
with rate voltage and frequency. 

Make sure that the available voltage is not higher than stated at the end of this manual. 

Make sure the power cord is never crimped or damaged by sharp edges. If this would be 
the case, replacement of the cable must be done by an authorized dealer. 

Always disconnect from the mains, when the device is not in use or before cleaning it. Only 
handle the power cord by the plug. Never pull out the plug by tugging the power cord. 

During initial start-up some smoke or smell may arise. This is a normal process and does 
not necessarily mean that the device is defective, it should decrease gradually. 

Please don't project the beam onto combustible substances. 

Fixtures cannot be installed on combustible substances, keep more than 50cm distance 
with wall for smooth air flow, so there should be no shelter for fans and ventilation for heat 
radiation. 

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively 
replaced by the manufacturer or his service agent or a similar qualified person in order to 
avoid a hazard. 

 

CAUTION

 

Be careful with your operations.With a dangerous voltage you can suffer 
a dangerous electric shock when touching wires!

 


 

IMPORTANT

 

Damages caused by the disregard of this user manual are not subject to 
warranty. The dealer will not accept liability for any resulting defects or 
problems.

 

Содержание Typhoon 600W dual white IP65

Страница 1: ...User Manual Squareled Typhoon 600W dual white IP65...

Страница 2: ...SquareLED Typhoon 600W dual white User Manual IP65...

Страница 3: ...must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the...

Страница 4: ...CAUTION Please pay attention below warnings before using this fixture...

Страница 5: ...aluminum casing with nice outlook The fixture is designed and manufactured strictly following CE RoHS standards complying with international standard DMX512 protocol It s available independently contr...

Страница 6: ...ast aluminum High strength single handle design Barn door included 4 kinds of dimming curve Dimming Frequency 500HZ 25000HZ optional Strobe 1 25times sec 5 DMX channels Control Protocol RDM DMX and Ma...

Страница 7: ...ale 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be...

Страница 8: ...scotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor c...

Страница 9: ...Main Menu 5 2 Operation Status Mode Display Description DMX Mode Dxxx D stand for DMX mode Temperature Mode M WP M stand for stand Master WP stand for White Point Reverse Display Running Status Vice...

Страница 10: ...ly after 5 seconds 2 Menu of DMX address DMX mode will turn into DMX menu automatically after 5 seconds DMX Menu Operation 1 DMX mode When the DMX 512 signal is connected correctly and the data of cha...

Страница 11: ...State Option Mark Touch Screen Calibration Touch Screen Calibration Dimmer Frequency Choose the dimmer frequency 500HZ Increase or decrease with data of 100HZ 25000HZ Dimmer Curve Choose the dimmer c...

Страница 12: ...rtation because it might damage the light due to the environment changes So make sure to operate the fixture until it is in normal temperature This light should be keep away from strong shaking during...

Страница 13: ...kept at least 0 5m 1 5 ft away from any flammable materials decoration etc Please ensure that the led fresnel spotlight is hung using the appropriate C clamp or half cheeseboro A safety chain or cabl...

Страница 14: ...nt practice if you want the fixtures to last So what is the maintenance for the fixture Clean the light Turn off the led fresnel spotlight Using a small vacuum cleaner suck the dust and fur balls out...

Страница 15: ...Das LichttechnikhausVertriebs GmbH Rudolf Diesel Str 3 D 89312 G nzburg Telefon 49 0 82 21 207 98 0 Fax 49 0 82 21 207 98 69 E Mail info lth gmbh de Web www lth gmbh de...

Отзывы: