Enable Nite Cycle  (OFF / ON) 

To Enable/

Disable

 

the Nite Cycle 

press the Enter button while on this display. 

 

Nighttime Temperature: 

This setting is the temperature the device will maintain during the Nite Cycle.

 

 

NiteCycle Start Time: 

This setting adjusts what time the Nite Cycle starts.

 

(Output Setup for Temperature Control continued...) 

 

NiteCycle End Time: 

This setting adjusts what time the Nite Cycle 

ends. 

 

Ramping: 

This setting adjusts how long it will take to switch between the DayTemp and NiteTemp

 settings allowing a 

smooth transition up to 10 hours.  

 

 

High / Low Alarms Menu: 

Enter this menu to set the audible High / Low Alarm feature. 

 

 

 

 

 

 

 

 

 

Enable H/L Alarm  (OFF / ON) 

To Enable/

Disable the 

High/Low Alarms press the Enter button while on this display. 

 

High Temp Alarm: 

This setting is the highest temperature at which the audible alarm triggers if breached. 

 

Low Temp Alarm: 

This setting is the lowest temperature at which the audible alarm triggers if breached. 

 

Low Alarm 30 min Mute (OFF / ON) 

 

This setting by default is disabled and is only available in temperature related modes.  This will mute the low 

temperature alarm for 30 minutes anytime the low alarm is triggered.  This is useful to allow time for the 

temperature to reach the target setting.  If the Low Alarm is triggered you can reactivate the mute by entering 

the menu or by pressing the PLUS button on the main display that shows the probe temperatures.  This will 

allow another 30 minutes before the Low Alarm becomes active again. 

 

Sensor Adjustment: 

The Sensor Adjustment setting is used to alter the temperature read by the temperature probe to match other 

equipment.  

Note:  The sensor used in the Herpstat Probes are typically more accurate than most other 

equipment.  Adjustments to this setting are usually not necessary. 

 

Temperature Swing: 

This controls the range of temperature.  In heating mode this is the amount of degrees it will allow to drop 

below your Daytime or Nitetime

 setting before turning the output back on.  In cooling mode the temperature 

must drop this amount below the Daytime Temperature or Nitetime Temperature setting temperature before the 

output will be turned off.  

 

Security Passcode 

 

From the initial menu screen select Security Passcode using the Plus and Minus button and press Enter.   

 

 

 

This setting creates a 4-digit Passcode that is required to be entered before menu access is granted.  Use the 

Plus and Minus buttons to toggle the individual digit and the Enter button to advance to the next digit.  Entering 

all zero's will disable the Passcode.  If the menu timeout expires while in this setting the Passcode will be 

disabled automatically.  If you forget this Passcode in order to regain access to the menu requires the device to 

be reset to factory defaults.  This can be done by holding down the Plus button while plugging the Herpstat into 

power.  All settings are lost in the reset process. 

Содержание Herpstat HP

Страница 1: ...re efficiency High Low threshold alarms Settings are retained in memory even if power is lost Power Outage detection tracking Temperature can be set displayed in Fahrenheit or Celsius Easy to read backlit LCD display 12ft removable sensor allows for easy replacement if necessary Audible alarm system Internal error detection shuts off heat if sensor fails or is disconnected Handles up to 1500 watts...

Страница 2: ...select options while the Plus and Minus buttons are used to alter the options or navigate the menu If no selection is made after a period of time the unit will return to operation automatically While in the menu system all AC power to the outputs are turned off for safety Note Adjust the Time to insure proper operation Press the Enter button to display the initial menu screen This screen allows yo...

Страница 3: ... the included temperature sensor for heating cooling modes and the optional humidity sensor for the RH mode Heat mode is for standard thermostat heating operation The Cooling mode applies power when the set temperature is exceeded The Cooling mode then powers off the output when the temp drops below the Swing setting Daytime Temperature The Daytime Temperature setting is the temperature the device...

Страница 4: ... PLUS button on the main display that shows the probe temperatures This will allow another 30 minutes before the Low Alarm becomes active again Sensor Adjustment The Sensor Adjustment setting is used to alter the temperature read by the temperature probe to match other equipment Note The sensor used in the Herpstat Probes are typically more accurate than most other equipment Adjustments to this se...

Страница 5: ...hieve is in parentheses When ramping is enabled for temperature the value in parentheses will change according to the time based curve Special Symbols Next to the number of the output an arrow symbol will appear if that output is currently in a ramping session A right arrow will appear if the ramp is increasing A left arrow will appear if the ramp is decreasing Next to the number of the output a m...

Страница 6: ...ices Preferably leave at least a few inches between the probe wires and the AC lines to avoid cross talk electrical interference issues Getting Help Questions or comments can be e mailed to support herpstat com To purchase accessories please visit us on the web at http www spyderrobotics com 1 Year Limited Warranty Spyder Robotics LLC warrants this product to be free from defects in workmanship an...

Отзывы: