Thank you for choosing the Herpstat digital proportional thermostat.  This product 

offers the following features: 

 

 

Proportional heating constantly monitors and adjusts amount of heat necessary to maintain a target 

temperature (usable range from 40˚F to 150˚F or 4˚C to 65˚C).   

 

 

Soft startup slowly applies power during initial warm-ups. 

 

 

Configurable for Heating, Cooling, Lighting, and Humidity.   

 

 

Lighting can simulate sunrise/sunset and moonlight. 

 

 

User selectable temperature and light ramping allows day to night changes to occur slowly.  

 

 

Sensor Matching allows the user to digitally calibrate the sensor output to match other equipment. 

 

 

Auto Power Matching constantly adjusts the power output curve to match the enclosures efficiency. 

 

 

Individually selectable day/night schedules with nighttime temperature settings for each output. 

 

 

High/Low temperature tracking helps monitor heating system and enclosure efficiency. 

 

 

Individually selectable High/Low temperature threshold alarms. 

 

 

Precision temperature sensors with an internal resolution of .1125 ˚F and are accurate to ± .9 ˚F 

 

 

Display and setting in tenths of a degree. 

 

 

Security Passcode option deters vandals.   

 

 

All settings are retained in memory even if power is lost. 

 

 

Power Outage detection/tracking. 

 

 

Temperature can be set/displayed in Fahrenheit or Celsius. 

 

 

Easy to read backlit LCD display. 

 

 

Removable sensors allow for easy replacement if necessary. 

 

 

User replaceable fuse. 

 

 

Audible alarm system 

 

 

Internal error detection shuts off heat if sensor fails or is disconnected. 

 

 

Internal safety relay cuts power to all outputs if user settable conditions are met. 

 

 

700 total watt output for the Herpstat 1  

 

 

900 total watt output for the Herpstat 2  

 

 

1 year limited warranty 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Herpstat 1

Страница 1: ...iciency Individually selectable day night schedules with nighttime temperature settings for each output High Low temperature tracking helps monitor heating system and enclosure efficiency Individually selectable High Low temperature threshold alarms Precision temperature sensors with an internal resolution of 1125 F and are accurate to 9 F Display and setting in tenths of a degree Security Passcod...

Страница 2: ...modate more types of heating devices Hardware Installation WARNING FIRE OR ELECTRICAL SHOCK MAY RESULT FROM MISUSE FOR INDOOR USE ONLY Herpstat 1 Do not exceed 700 watts Herpstat 2 Do not exceed 500 watts on either output or 900 total watts 1 Each AC receptacle on the Herpstat has a corresponding probe jack next to it For heating or cooling use attach a temperature probe For humidity control an op...

Страница 3: ... settings if a different temperature is required during the night Output Setup for Temperature Control continued Enable Nite Cycle OFF ON To Enable Disable the Nite Cycle press the Enter button while on this display Nighttime Temperature This setting is the temperature the device will maintain during the Nite Cycle NiteCycle Start Time This setting adjusts what time the Nite Cycle starts NiteCycle...

Страница 4: ...mooth transition up to 10 hours Output Setup for Humidity Control From the initial menu screen select an output using the Plus and Minus button and press Enter Output Mode RH Scheduled RH Sensed RH Hybrid Note When the Mode is changed all settings for selected output will be set to the defaults for that particular mode RH Sensed and RH Hybrid mode require the optional Herpstat Humidity Sensor sold...

Страница 5: ...is triggered which cuts the main power to all the outputs ALL OUTPUTS IF Low Alarm Error This option enables the built in safety relay If any Low alarm condition is set and is breached all outputs will be turned off and the safety relay is triggered which cuts the main power to all the outputs ALL OUTPUTS IF High Alarm Error This option enables the built in safety relay If any High alarm condition...

Страница 6: ...r the menu and perform the Master Reset option under the System Settings menu Do not cover the probe tip with aluminum tape This will cause false readings and poor regulation If possible route the probe wires so that they are not in direct contact with the 120vac cables going to the heating devices Preferably leave at least a few inches between the probe wires and the AC lines to avoid cross talk ...