![SPXFLOW APV CU4plus AS-i Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/spxflow/apv-cu4plus-as-i/apv-cu4plus-as-i_instruction-manual_1352861045.webp)
APV_CU4plus_AS-interface_UK-3_062019.indd
UK
Control Unit
CU4plus AS-interface
Instruction Manual UK-3
APV
45
sensor 2
(TeachSignal)
sensor 1
(TeachSignal)
8. CU Assembly and Startup
8.3.
Double seat valve DA3+ with activated Seat Lift Detection (SLD)
Assembly of the control unit on the valve
1.
Assembly of the adapter on the double seat valve. Fasten with
4 screws.
2.
Align air connections of the control unit to the valve actuator.
3.
Place the control unit onto the adapter. Observe alignment!
4.
Attach the clamp rings and fasten them with the screws.
5.
Assemble the external proximity switches at the actuator.
CU cover
CU43plus
clamp ring
linear sensor
fastening screws
magnetic switching cam
CU adapter
guide rod extension
seat lift cylinder
main actuator
spring cylinder
sensor 3
sensor 4