GENERAL INFORMATION

1.1

WARNINGS, CAUTIONS AND NOTES

Within this handbook, pay particular attention to Warnings, Cautions, and
Notes, examples of which are shown below.

I

NDICATES THE POSSIBILITY OF PERSONAL INJURY IF INSTRUCTIONS ARE

NOT FOLLOWED CAREFULLY

.

C

Indicates a possibility of equipment damage if the instructions are not

followed carefully.

S

INDICATES SERVICEABLE PARTS

N

NOTE. Gives added information that will make operation of the equipment

easier.

1.2

SAFETY PRECAUTIONS

C

The P374 Inspection System is designed to reduce hazards from electric
shock provided that proper operating procedures are followed. If it is
operated in an outdoor environment it is imperative that proper earthing
procedures are followed. Use of a Residual Current Detector (RCD) is
strongly recommended [USA - Ground Fault Interrupter (GFI)]

Ensure the system is not placed in or near surface water.

Always ensure that cabling is properly connected.

Always transport a generator with the minimum amount of fuel in the
tank.

Never connect or disconnect any part of the equipment when it is switched
on.

Always switch the system on and off using the mains supply switch.

Clean and sterilise equipment at regular intervals.

A

LWAYS USE HEAVY DUTY INDUSTRIAL GLOVES WHEN HANDLING ROD OR

CABLE WHICH IS BEING WITHDRAWN FROM A SEWER

.

T

O AVOID RISK OF BURNS

,

DO NOT TOUCH THE CAMERA HEAD WHEN IT IS

SWITCHED ON OR IMMEDIATELY AFTER SWITCH OFF

. L

EAVE AMPLE TIME

FOR IT TO COOL BEFORE HANDLING

.

A

RISK ASSESSMENT SHOULD BE PERFORMED PRIOR TO COMMENCING

WORK AS IT MAY HIGHLIGHT ADDITIONAL SAFETY ISSUES SPECIFIC TO THE

APPLICATION

1-1

Содержание Pearlpoint P374

Страница 1: ......

Страница 2: ......

Страница 3: ...modify and update the equipment at any time without prior notice No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means to a third party...

Страница 4: ...3 3 P374 INTRINSICALLY SAFE FLEXIPROBE 3 1 3 1 SETTING MANUAL FOCUS 3 1 3 2 SKID SETS 3 3 3 3 FITTING 100MM 4 BRUSH SKIDS 3 4 3 4 FITTING 100MM 4 AXIS SKIDS 3 5 3 5 FITTING 100MM 4 AXIS SKIDS LIVE GAS...

Страница 5: ...DELETING A LINE 4 4 4 15 DELETING EVERYTHING ON A PAGE 4 4 4 16 DELETING EVERY PAGE 4 5 4 17 CORRECTING A CHARACTER 4 5 4 18 INSERTING A CHARACTER 4 5 4 19 INSERTING A LINE 4 5 5 SPECIFICATIONS AND T...

Страница 6: ...tive that proper earthing procedures are followed Use of a Residual Current Detector RCD is strongly recommended USA Ground Fault Interrupter GFI Ensure the system is not placed in or near surface wat...

Страница 7: ...P374 System User Manual Section 1 Pearpoint Ltd 2 5 1 3 SIRA CERTIFICATION 1 2...

Страница 8: ...Section 1 P374 System User Manual Pearpoint Ltd 2 6 1 3...

Страница 9: ...P374 System User Manual Section 1 Pearpoint Ltd 2 7 1 4...

Страница 10: ...Section 1 P374 System User Manual Pearpoint Ltd 2 8 1 4 FM CERTIFICATION 1 5...

Страница 11: ...P374 System User Manual Section 1 Pearpoint Ltd 2 9 1 6...

Страница 12: ...following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to whic...

Страница 13: ...P374 System User Manual Section 1 Pearpoint Ltd 2 11 1 8...

Страница 14: ...c electricity and this may be discharged through the P374 system When working with a generator it is imperative that the generator is earthed this can be done via the generator earthing point see the...

Страница 15: ...P374 System User Manual Section 1 Pearpoint Ltd 2 13 1 10...

Страница 16: ...l use of bubble pack or polystyrene material to cushion and prevent movement of the component Clearly identify all equipment with the customer s name and address Where relevant attach Fragile and This...

Страница 17: ...this can display the users text messages on screen along with the cameras distance measurement and the date and time this is updated automatically The system is fully water resistant to IP55 allowing...

Страница 18: ...tor straight on the picture quality will degrade when viewed from different angles You can adjust the quality of the displayed picture by using the monitor set up controls situated on the left hand si...

Страница 19: ...basis to confirm the absolute accuracy of your counter by means of a physical check of rod length This involves calibrating the rod setting the counter to zero and pulling 20m 60 ft of rod from the c...

Страница 20: ......

Страница 21: ...ated in a anti clockwise direction Once the lens has been focussed to infinity it is easy to judge where to set the lens for normal use the lens will only need to be turned one half turn anti clockwis...

Страница 22: ...cus until the chart is in sharp focus try moving the camera slightly upward and downward to check that the focus is at its sharpest point The camera is now ready for inspecting 4 100mm pipework If you...

Страница 23: ...be damaged 3 2 SKID SETS There are three different types of skid sets available with the P374 100mm 4 Radial brush skids are recommended for clean pipes Part No HC3730901 1 50mm 2 Delrin skids without...

Страница 24: ...Press the brush ring flush with the front half skid 4 Fix the back two halves item 3 4 of the front skid together ensuring to lock the flange over the collar of the front half of the skid 5 Secure wi...

Страница 25: ...he collar of the front half so that the brushes slide into the slots of the rear quadrants 3 Secure with the two M4x4 socket head cap screws To fit the rear skid 1 Place the front two halves of the ba...

Страница 26: ...lange over the collar of the front half so that the brushes slide into the slots of the rear quadrants 3 Secure with the two M4x4 socket head cap screws To fit the rear skid 1 Place the front two halv...

Страница 27: ...lean out any debris from the LED recesses Looking after your camera To preserve the picture quality it is important that the sapphire window in front of the lens and the LED lighting is kept clean and...

Страница 28: ...sembly The sapphire window cannot be replaced separately as this is bonded to the lens to provide a waterproof seal This is quite a simple process but requires that the camera is perfectly clean befor...

Страница 29: ...ped in Isolpropyl Alcohol IPA as other cleaning agents may mark the glass face of the CMOS sensor In all cases clean the thread area as this will probably have an amount of debris build up Always ensu...

Страница 30: ...ds as these are fine pitch you should need only a small amount of pressure to overcome the compressed air behind the lens Screw the lens in carefully until the top surface is below the body of the cam...

Страница 31: ...IT These are indicated on the labels above each of the FUNCTION keys F1 to F3 respectively You then press the appropriate F key to show the next level of choice To move back up the tree press the ESC...

Страница 32: ...R or IMP 4 7 SET DISPLAY COLOUR CONF DISP You can select the colour of the display text You can select BLACK or WHITE 4 8 SYSTEM RESET CONF FCLR FCLR is short for Forced Clear If you select this optio...

Страница 33: ...y If you begin getting the wrong characters eg instead of 1 this means that the shift lock is wrongly set Change it by pressing the key N NOTE The screen displays the selected page The selected page n...

Страница 34: ...ess the DEL key twice The entire field will be deleted 4 13 DELETING A CHARACTER A character can be deleted by using the CURSOR ARROW keys to move the cursor over it and then 1 Pressing DEL twice remo...

Страница 35: ...ect character This is called overtyping 4 18 INSERTING A CHARACTER A character can be inserted by moving the cursor to the right or left of the position where the character is to be inserted Pressing...

Страница 36: ......

Страница 37: ...Check power supply Camera lights and LCD do not operate Power lead disconnected or damaged Reconnect power lead or if damaged replace lead Rod damaged or broken Inspect rod If damaged or broken seek a...

Страница 38: ...Section 5 P374 System User Manual Pearpoint Ltd 5 2...

Страница 39: ...w...

Страница 40: ...7 w...