background image

© SPX Corporation

Sheet No.

Issue Date:      Rev. 12-22-97

Parts List & Operating Instructions

Form No. 102610

2 of 2

Operating Instructions

1. Place an approved waste oil container under the oil filter crusher's drain hole.

2. Connect the pump to shop air regulated at 100 PSI maximum.

3. Lift the ram shield, and center the oil filter over the drain hole in the  counterbore. The filter’s open end (the sealing area

containing the o-ring) must be facing down toward the drain hole as shown in Figure 4. When the oil filter is crushed,
the oil will be forced into the hole.

4. Close the ram shield, and press the START button on the pump. The pump will build pressure and then automatically

shut off and release pressure. Do not open the shield until the cycle is complete and the pump shuts off. If it is necessary
to interrupt the cycle, pull the START button out. The pump will stop and the ram will retract.

5. Open the ram shield and remove the crushed filter, being careful not to scratch, cut, or puncture your skin on the filter’s

sharp edges. See Figure 5.

6. Recycle or dispose of waste oil and oil filters according to local, state, and federal regulations.

Figure 4

Figure 5

Maintenance

1. Maintain the oil level in the pump reservoir according to operating instructions included with the pump.

2. Regularly inspect hoses for signs of wear or stress, and replace as needed.

3. Keep the eight tie rod nuts torqued at 300-320 ft. lbs.

4. Keep the override switch in working order.

ram shield

Refer to any operating instructions included with the product for detailed information
about operation, testing, disassembly, reassembly, and preventive maintenance.

Items found in this parts list have been carefully tested and selected by OTC.

Therefore: Use only OTC replacement parts!

Additional questions can be directed to our Tech. Services Dept. at 1-800-533-6127.

oil filter

Отзывы: