2.  Location in the compressed air system

A.           

  Maximum working pressure - 250 psig,  

17.6 kgf/cm

2

.  Do not exceed unit’s Maximum Working 

Pressure.

  1)  For maximum capacity, install unit in air system at    

      highest pressure possible (e.g. before pressure  

 

      reducing valves) 

  2)  For maximum capacity, install unit at coolest  

 

      compressed air temperature possible.  Maximum    

      inlet compressed air temperature: 180°F, 82°C.  If    

      inlet air exceeds this temperature, precool the air    

      by extending the piping between the compressor    

      and the dryer.  

B.  Air Outlet - Connect air outlet to downstream air lines.

C.  By-pass piping - If servicing the unit without interrupt-

ing the air supply is desired, piping should include inlet 

and outlet isolation valves and an air by-pass valve.

D.  Condensate drain - It is advisable to connect drain 

outlet to the condensate drainage system.

NOTE: Drain discharge is at system pressure. Drain line 

should be anchored to prevent whipping.

1.4  Electrical connections 

A.  Dryer is designed to operate on power supply (voltage) 

listed on serial number tag located on the back of the 

dryer.

B.  Dryer is supplied with an electrical cord.  Install in re-

ceptacle of proper voltage.       

NOTE:  Models 50 and 75 (115v only) - Install plug 

in receptacle rated for 20 amps.  Units are sup-

plied with 20 amp plug.

NOTE: Refrigeration system is designed to run continu-

ously and should NOT be wired to cycle on/off with the air 

compressor.  

1.0  InStallatIon

1.1  Location  

A.  Air compressor intake - Locate air compressor so that 

contaminants potentially harmful to the dryer are not 

drawn into the air system.  

B.  Free air flow -  Do not block either side of the cabinet.  

Observe minimum installation clearances as shown.

1.2  Mounting 

Dryer is suitable for floor or shelf mounting.

1.3  Piping connections 

A.  Air Inlet - Connect compressed 

air line from air compressor to 

air inlet using strainer supplied.    

  1.  Install strainer (included in 

shipping carton) prior to 

dryer inlet using pipe nipple 

supplied or other piping as 

required.

NOTE: Observe flow direction arrows on strainer.

NOTE: Install strainer where it is easily accessible for clean-

ing.

NOTE: Use vibration dampener, if vibration exists in air line 

at inlet to dryer.

24"

12"

wall

6"

36"

Plug

Содержание HANKISON HIT 100

Страница 1: ...ectrical codes Standard equipment is supplied with NEMA 1 elec trical enclosures and is not intended for installation in hazardous environments Disconnect power supply to equipment when per forming an...

Страница 2: ...at system pressure Drain line should be anchored to prevent whipping 1 4 Electrical connections A Dryer is designed to operate on power supply voltage listed on serial number tag located on the back o...

Страница 3: ...Flow capacity in scfm m3 min 180 F 82 C inlet temperature 160 F 71 C inlet pressure dew point 95 F 35 C ambient temperature 50 F 10 C outlet pressure dew point and less than 5 psi 0 35 kgf cm2 pressu...

Страница 4: ...off compressed air supply to the dryer and depressurize B Remove top panel C Remove two screws holding side panel and remove side panel by sliding upwards D Disconnect drain tube from bulkhead fittin...

Страница 5: ...surize B Remove top panel C Remove two screws holding side panel then remove side panel by sliding upwards D Disconnect drain tube from bulkhead fitting in cabinet base To remove press the plastic col...

Страница 6: ...erature 3 Unit functioning normally but ther mostatic switch is malfunctioning or not securely mounted a Power failure b Line disconnect switch open c Blown fuses open breaker d Faulty wiring loose te...

Страница 7: ...psig 16 9 12 7 kgf cm2 Air Flow Across Condenser cfm m3 min 60 50 Hz 60 50 Hz 280 235 7 9 6 7 620 515 17 6 14 6 Electrical Data Unit VAC phase Hz 115 1 60 115 1 60 Minimum maximum volts 98 127 Full L...

Страница 8: ...gf cm2 Air Flow Across Condenser cfm m3 min 60 50 Hz 60 50 Hz 830 690 23 5 19 5 Electrical Data Unit VAC phase Hz 208 230 1 60 230 1 60 Minimum maximum volts 187 253 Full Load AmpS FLA 11 7 Branch Cir...

Страница 9: ...R C S 6 REFRIGERANT COMPRESSOR 4 4 HIGH 4 WIRING SCHEMATIC Models 100 and 125 All Voltages FPS TB HTS FM OLT LT SW M Front of Dryer Outside Right Side of Dryer Inside COMPONENT LOCATIONS RC Models 20...

Страница 10: ...dels 20 25 35 Model Weight 20 79 lbs 36 kg 25 80 lbs 36 kg 35 81 lbs 37 kg 718 mm 317 mm 105 mm 1 9 16 40 mm 5 mm 217 mm 1 25 mm 6 mm 257 mm 5 1 16 128 mm 257 mm 216 mm 41 mm 130 mm 105 mm 287 mm 1 1...

Страница 11: ...and Weights Models 50 and 75 Model Weight 50 150 lbs 68 kg 75 155 lbs 70 kg 933 mm 117 mm 1 1 2 38 mm 429 mm 5 mm 419 mm 25 mm 21 mm 15 1 4 387 mm 8 7 16 213 mm 425 mm 6 mm 129 mm 39 mm 175 mm 160 mm...

Страница 12: ...12 Dimensions and Weights Models 100 and 125 Model Weight 100 187 lbs 85 kg 125 189 lbs 86 kg 1 1...

Страница 13: ...0872 3220872 3220872 3220878 3220878 Capacitor run 208 230 1 60 3220878 3220878 3220878 3220878 3220878 Switch fault light w conn 3240331 3240331 3240331 3240597 3240597 Condenser Fan Fan Motor 115 1...

Страница 14: ...Capacitor run 230 1 60 3065778 3065778 Capacitor run 220 240 1 50 3065778 3065778 Switch fault light w conn 3240597 3240597 Condenser Fan Fan Motor 3227986 3227986 Fan Blade 3219404 3219404 Refrigerat...

Страница 15: ...15 NOTES...

Страница 16: ...RESSLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRAN TY OF FITNESS FOR A PARTICULAR PURPOSE THE MANUFACTURER SHALL NOT BE LIABLE FOR LOSS OR DAMAGE BY REASON OF STRICT LIAB...

Отзывы: