SPX Fluid Cooler Marley MC Скачать руководство пользователя страница 6

 Frequently Asked Questions

Why should I purchase a fluid cooler instead of a cooling tower/heat exchanger combination?

A

 

 Fluid coolers reduce piping and system complexity by combining three pieces of equipment (cooling tower/ 

heat exchanger/pump) into one unit. This can prove beneficial in critical application areas.

 

 In addition, a cooling tower and heat exchanger usually have a combined approach temperature of about 4°C. 

With a closed circuit fluid cooler, certified approaches as low as 3°C can be guaranteed – allowing for colder 

process fluid temperatures and greater efficiency during operation.

 

 Closed circuit systems also protect the process fluid from contamination – reducing fouling and scaling  

tendencies within sensitive systems. Clean closed loops result in greater efficiency, reduced energy costs  

and reduced maintenance costs.

What are some common closed circuit/fluid cooler applications?

A

 

 Typical closed circuit applications include any process that is sensitive to fouling and corrosion. Many HVAC 

applications are ideal for fluid coolers. Fluid coolers are also ideal for installations where the process fluid  

is something other than water. Although certified with water as the process fluid, the MC Fluid Cooler can 

effectively discharge heat from other fluids such as glycol, oil or other unusual water mixtures.

 

Common applications for the MC Fluid Cooler:  

Common sites for the MC Fluid Cooler:

 

 Water source heat pumps 

 Cooling special fluids 

 Condominiums 

 

 Self-contained cooling 

 Compressor jacket cooling 

 Steel mills 

 

 Chillers 

 Machine jacket cooling 

 Power plants 

 

 Free cooling 

 

 Schools 

 

 

 

 Hospitals

Why would I install a 

forced draft

 fluid cooler over other fluid cooler configurations?

A

 

 There are a number of reasons why a 

forced draft

 fluid cooler might be the smartest choice:

 

 

Low energy and water consumption

 – forced-draft fluid coolers can alternately operate in a dry cooling  

mode if ambient conditions are favorable. This minimizes energy and water consumption, saving money  

while conserving natural resources. For situations that require greater 

electrical

 energy savings, consider  

the Marley MH Fluid Cooler.

 

 Low noise

 – centrifugal fans and a fully-enclosed falling water area work to create one of the quietest  

fluid cooler configurations on the market.

 

 

Small footprint

 – a forced-draft, counterflow design requires considerably less plan area than  

crossflow towers.

 

 High static

 – the capability of centrifugal fans makes it ideal for ducted applications, indoors or out.

Can a fluid cooler be used in freezing weather applications?

A

 

 Yes, but care must be taken to ensure proper operation and orientation (preventing recirculation).  

By maintaining sufficient flow rate and heat load on the process fluid, a closed circuit tower can be  

utilized in almost any environment.

 

 Fluid exiting the coil must be maintained at or above 7°C. Cycling of the recirculation should not be used  

to control process temperatures. Instead, introduction of ethylene or propylene glycol solutions is the best 

means to protect the coil. For more severe fluid cooler freezing environments, we recommend the Marley  

MH Fluid Cooler.

Содержание Fluid Cooler Marley MC

Страница 1: ...Marley MC Fluid Cooler Balcke Hamon Dry Cooling Marley...

Страница 2: ...Unmatched reliability Heavy duty construction high performance design and our five year mechanical warranty ensure consistent fully rated cooling over a wide range of flow and temperature requirements...

Страница 3: ...maintenance An extra large entry panel makes the interior of the unit easy to access for service and maintenance For even greater access the motor and drive are located outside the plenum area near t...

Страница 4: ...rs guarantee drift rates 0 005 Distribution system access via an optional ladder or platform Extra large rectangular access doors for easy maintenance Optional S300 construction for extended life 5 ye...

Страница 5: ...exibility during design Vibration switch protects against mechanical failure should the tower experience high vibration levels Automatically shuts down the motor Manual reset ensures inspection to cor...

Страница 6: ...ds Condominiums Self contained cooling Compressor jacket cooling Steel mills Chillers Machine jacket cooling Power plants Free cooling Schools Hospitals Q Why would I install a forced draft fluid cool...

Страница 7: ...MCF7054_121 57 73 3555 2390 4625 5125 MCF7055_081 81 91 3555 2390 4165 5555 MCF7055_101 90 101 3555 2390 4395 6325 MCF7055_121 97 108 3555 2390 4625 7085 MCF7073_081 42 49 2665 2970 4165 4115 MCF7073_...

Страница 8: ...LER PUBLICATIONS For further information about the MC Fluid Cooler including engineering schematics data layout requirements and more ask your Marley sales representative for a copy of the following p...

Отзывы: