26
Maintenance
CRL/EN (1810) 2.2
5.5
Noise
If a pump starts making noise, this may point to certain problems with the pump unit. A
crackling noise can indicate cavitation or excessive motor noise can indicate
deterioration of the bearings.
5.6
Motor
Check motor specifications for start-stop frequency.
5.7
Faults
The pump, of which you want to determine the fault, may be hot or under
pressure. Take the appropriate precautions first and protect yourself with
the proper safety devices (safety goggles, gloves, protective clothing)!
To determine the source of the malfunctioning of the pump, proceed as follows:
1 Switch off the power supply to the pump unit. Lock the working switch with a padlock
or remove the fuse. In case of a combustion engine: switch off the engine and close
the fuel supply to the engine.
2 Close the stop valves.
3 Determine the nature of the fault.
4 Try to determine the cause of the fault with chapter 6 "Problem solving" and take the
appropriate measures or contact your installer.