14. Trouble Shooting
Failure
Remedy
Valve closed
Leakage at discharge side
Replace seat seal
(2, 2.1)
.
Check line pressure
(max. 10 bar)
.
Check control of seat lift actuator.
Leakage between housing and yoke flange
Check housing seal
(7)
and shaft seal
(4, 5)
, replace
damaged seals.
Leakage at valve shaft
Replace shaft seal
(4, 5)
.
Spring cylinder
Correction at spring cylinder is not possible.
Replace complete spring cylinder
(21)
.
Seat lift actuator
Seat lift actuator does not work
(air escapes permanently from the shaft rod).
Replace o-ring
(19)
.
Seat lift actuator does not work
(air escapes permanently from the vent bore).
Replace complete spring cylinder.
Do not open cylinder by force. Spring force!
Valve position indication
No feedback.
Carry out fine adjustment.