Model Number 

Cooling Capacity

,000BTU/hr

Heating Capacity (1)(2)

N/A

Power Consumption 

Humidity Removal Capacity 

 pts./day 

Recommended Room Size* 

Power Supply 

Compressor  

Refrigerant

Fan Speed 

2

Timer 

Thermostat

°F - 90°F

Net Weight 

 lbs. 

Dimensions

17"W x 17"D x 30 "H

Working Temperature 

        REMARKS: 

        1. The data may vary, please refer to the rating label on the back on the back of the unit. 

        2. The above conditions are measured at: 
            Cooling - Indoor: RT 81°F, RH 60% 

        * Uninsulated rooms such as sunrooms, garages, or attics should be less than 

 sq. ft. 

Specifications

R-22 

Rotary 

 1-12hours 

 

2

Drainage

During the process of cooling , some water will be extracted from the air into the unit.  Most of
this water is used to cool the unit and make it run more efficiently. This is a feature not found in most
Portable Air Conditioners.  If the unit is operated in VERY HUMID air, water will collect in the container
inside the unit. If the water container is full, the compressor and fan will stop. The 

 indicator will

blink to inform you to empty the  
internal container. To make the cooling function work again, please
empty the water by one of the following methods: 

By the Draining into a Container

Use a Shallow Container or Dish 
1. Turn off the unit. 
2. Position a flat container or dish under the drain hole. 
Do not allow the water to drip continuously into the container, as it
might easily overflow. 
3. Remove the drain knob & rubber plug from the drain hole. The 
condensed water will drain out automatically. 
4. When the container is almost full, replace the rubber plug into 
the drain hole to stop the water. Empty the container. 
5.  Repeat steps 2, 3 & 4 until all the condensed water is emptied.
6.  Once all the condensed water has been removed, replace the 
rubber plug into the drain hole firmly. The Full Water indicator 
should be off now. 
7.  Replace the drain knob. 
* Do not allow the water to drip continuously into the  tray, as it 
may easily overflow. 

By Water Tube (Continuous Drainage) 

1. Remove the drain knob and rubber plug and keep them for 
future use. 
2. Use Teflon tape to cover threading on spout, making a flat 
surface for the hose. This will prevent leakage. 
3. Connect a suitable water tube (of 3/4" internal diameter - 
supplied) to the water hole. The condensed water will drain out 
automatically.
4. If you want to extend the water tube you can connect it with 
another tube (outside diameter ¾”). 

Rubber Plug

Drain Knob

Water Hole

Rubber Plug

Drain Knob

Drain Pipe

riginal Water Tube

Extended Water Tube
(OD: 3/4")

O

9

Cooling: 62°F to 110°F 

 sq. ft. 

50

2

50

50

2

 O P

M

C

Содержание WA-9020E

Страница 1: ...inated representative The warranty will be void if the product is modified misused or repaired by an unauthorized person The guarantee after repair or replacement will not be extended beyond the origi...

Страница 2: ...lease store the power cord away shown in Figure 3 Thank you for choosing the portable air conditioner from SPTUSA a leading brand in indoor air treatment We would like you to enjoy the many benefits t...

Страница 3: ...o avoid the possibility of dangerous overheating If the supply cord is damaged it must be replaced by the service agent or a similarly qualified person THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF...

Страница 4: ...s will increase or decrease your set temperature by 1 F When pressing the temperature up or down buttons the window will change to display your set temperature At this time the green indicator will li...

Страница 5: ...is specially designed according to the specification of this product Do not replace or extend it with your own hose as this could cause the unit to malfunction 5 Mounting the exhaust pipe The supplie...

Страница 6: ...ntainer Use a Shallow Container or Dish 1 Turn off the unit 2 Position a flat container or dish under the drain hole Do not allow the water to drip continuously into the container as it might easily o...

Страница 7: ...to do nothing Is the dust filter dirty Is the air intake or outlet blocked up Is the temperature within the selected temperature 5 F Is the water tank full Drain the water The room is not cold enough...