SPARCIN 9 / SPARCIN 9C
13
7. MAINTENANCE
Daily
Inspect and, if necessary, change nozzle, electrode and electrode insulator.
Empty and, if necessary, clean the moisture trap situated on the rear of the machine. This is
easily done by pressing the bottom sealing of the glass cover while compressed air is
connected, or completely unscrewing the cover and cleaning it from dirt. Disconnect
compressed air or gas before unscrewing the glass cover.
Carefully inspect the torch body and the hose assembly with regard to any damage or leakage
of air, gas or water, mechanical damage or other.
NEVER
USE A TORCH WITH A DAMAGED TORCH BODY OR HOSE ASSEMBLY!
Every six months
Remove the plates from the machine. Inspect cable connections. Blow away dust and dirt with
compressed air.
Check coolant level, if necessary, fill up with distilled or de-ionised water.
Coolant conductivity: <5µS/cm.
Fill up with anti freezing agent when necessary. When the machines leaves the factory the
coolant consists of 70% de-ionised water and 30% pure mono-ethylene-glycol.
NOTE! The anti freezing agent must be pure glycol!