16
Specifications
Function
Specification
Comments
CONTROL ACTION
DUAL LOOP PROPOR INTEGRAL
FEEDBACK METHOD
ARMATURE VOLTS
TACHOMETER
SWITCH SELECTABLE
0-100% REGULATION
2% TYPICAL
0.1% TYPICAL
BEWARE MOTOR HEAT
AT LOW SPEED
MAX TORQUE SPEED RANGE
20 : 1
100 : 1
OVERLOAD
150% CONTINUOUS CURRENT FOR 30 SECONDS
Customer Presets
MAX SPEED
25 - 400 V FULL SCALE FEEDBACK
SWITCH SELECTABLE
MIN SPEED
0-30% OF MAX SPEED
NON-INTERACTIVE
UP/DOWN RAMPS
INDEPENDENTLY ADJUSTABLE 1-30 SECONDS
LINEAR RAMPS
STABILITY
VARIES SPEED LOOP GAIN
IR COMPENSATION
0-30% OF ARMATURE VOLTAGE
DO NOT USE WITH TACHO
MAX CURRENT
LINEAR SETTING FROM 0-100%, 4 SWITCHED RANGES
150% OVERLOAD
Switch Selectable
CURRENT RANGE
FOUR RANGES OF ARMATURE CURRENT
S1, S2
SPEED RANGE
FOUR RANGES OF FEEDBACK VOLTAGE
S3, S4
RELAY FUNCTION
DRIVE STALL OR ZERO SPEED RELAY
S5, S6
POWER UP HOLD
POWER UP INSTALL OR RUN MODE
S7
TACHO/AVF
SELECT TACHO OR ARMATURE VOLTAGE FEEDBACK
S8
Jumper Functions
TORQUE MODE
0-10 V INPUT FOR 0-100% CURRENT WITH AUTOMATIC
OVERSPEED PROTECTION
JUMPER SELECTABLE
SUPPLY SELECT
DUAL SUPPLY VOLTAGE SELECTOR
JUMPER SELECTABLE
Link Functions
4-20 mA OR 0-20 mA LOOP
ALLOWS CURRENT LOOP SIGNAL INPUT FOR SPEED
5 V COMPLIANCE
50% STALL LEVEL
ALLOWS LARGE PEAK CURRENTS
150% PEAK
SUPPLY RANGES
LV30
LV60
110
240
415
OVER FULL TEMP RANGE WITH
OUTPUTS LOADED
45 Hz to 65 Hz
MAX
36 V
72 V
130 V
264 V
440 V
AUTO RANGING
MIN
27 V
54 V
100 V
200 V
360 V
AC POWER RESET
MINIMUM OFF TIME BEFORE RE-SUPPLY
500 ms
RUN LINE
60 ms ON, 20 ms OFF. ALWAYS USE A RUN CONTACT TO
ENABLE THE DRIVE
AFTER
THE APPLICATION OF AC
SIGNAL OUTPUTS
SPEED, CURRENT, RAMP, DEMAND
ALL BUFFERED
SIGNAL INPUTS
3 SPEED INPUTS -/+ RAMPED, DIRECT, ALL SUMMING
PROTECTED
RELAY OUTPUTS
STALL OR ZERO SPEED RELAY
VOLT-FREE CHANGEOVER
RELAY DRIVERS
STALL, ZERO SPEED OPEN COLLECTOR PNP
FOR -24 Vdc 100 mA MAX
RAIL OUTPUTS
-24 V UNREGULATED 10 mA
+/- 20%
+12 V, +10 V, -12 V REGULATED 10 mA
0.01%/DEG C 5%
FIELD OUTPUT
0.9 (0.45) x AC SUPPLY. 1600i 1 A, 3200i 2 A.
FULL (0.9) OR HALF WAVE (0.45)
IP RATING
IP00
ALTITUDE
3000 METRES MAX FOR FULL RATING
DE-RATE 1%/100m
HUMIDITY
85% R.H AT 40ºC, NON-CONDENSING
FORM FACTOR
TYPICAL 1.5 AT MAX OUTPUT
TEMPERATURE
STORAGE AND OPERATING -10 TO + 50ºC
ARMATURE TIME CONSTANT MINIMUM 10 ms. USE EXTRA ARMATURE CHOKE TO
INCREASE
T= INDUCTANCE/RESISTANCE
MAX I
2
t FUSING
(Amps
2
Seconds)
1600i = 365
3200i/8 = 365, 3200i/16 = 555, 3200i/32 = 940,
3200i/48 = 4750
SEMICONDUCTOR FUSES
6
6
Specifications
Specifications
Содержание 1600i