![Spring Well CSS+ Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/spring-well/css/css_installation-instructions-manual_1351544019.webp)
Testing the System
92) While the water is still off,
open a cold bathtub faucet all
the way.
93) Before turning on the water to
the home ensure the shut off valve
to the system is in the off position.
91) Before turning the water
back on to the home, use the
provided spanner wrench to
fully tighten the pre-filter
housing.
94) Ensure that the valves on
both tanks are set to bypass.
96) If no leaks are detected,
open the bypass valve to allow
water flow through the tank
bypasses.
99) Allow water to run through
the system for 5-10 minutes. It is
normal to see a small amount of
sediment during this time.
Questions? Call (800)-589-5592
19
Whole House Filter and Water Softener
Off
Bypass
Bypass
95) Turn on the water to the
home and inspect the shut off
valve for any leaks.
97) If no leaks are detected
from the bypass, turn off the
bypass to the carbon filter tank
and allow water to flow
through it.
98) Turn off the bypass to the
softener tank and allow water
to flow through it.
If you notice water leaking from the carbon filter tank head
collar, please proceed to page 23 for directions on how to
adjust.