Before You Begin:
www.springusa.com
Stainless Steel Multi-Ply
Cookware
Carbon Steel
Aluminum Cookware with
Induction Disc
Cast Iron
Suitable Serving Ware:
Convertible Buffet Servers
Your MAX Induction
®
Warmer works with induction-ready serving vessels.
Visit the Spring USA Website for a full line of induction-ready, profes-
sional serve ware.
Serving pieces must have a flat bottom, in order to make full contact with
the countertop.
Serving pieces that are footed, or that have a raised ridge, are not for use on
this system, as they cannot make full contact with the counter surface.
Vessels must have a diameter greater than 9”.
Glass Cookware is not suited for use on your induction warming system.
Serving vessels must be centered on the induction warmer for optimal
heating and performance.
Aluminum Tray With Induction
Disk
Read the following instructions in their entirety. Use proper serving
vessels. All serving vessels must be induction-ready.
Your MAX Induction
®
Warmer must have proper ventilation in order to
operate correctly. There must be at least 7” of space available under a
mounted induction warmer. Cabinets housing the induction warmers
should have intake & exhaust vents. For optimal performance, the inside
temperature of the cabinet should not exceed 90°F / 32° C.
Ensure that you have dedicated power to the installed location. Each induc-
tion warmer will draw 5.4 Amps (International Model will draw 2.7 Amps).
Induction Range Error Codes:
Error
Cause
Solution
4 Flashing
Lights on
Control Panel
Range does not detect a pan on the
range.
Place an induction ready pan on the
range.
Low & Med-
High Lights
Flashing
Overheating protection has been
activated & the range has been
shut down.
Remove the cookware from the
range. Let the unit cool down, then
restart. Make sure the cookware
you are using is induction ready.
Low & High
Lights Flash-
ing
Range is experiencing temporary
voltage overload.
Let the induction range cool down
completely, before restarting. Re-
view dedicated power requirements
on page one of this manual.
Low & Low-
Med Lights
Flashing
Range has overheated due to
blocked ventilation and has shut
down the range.
Clear vents, let range cool down,
then restart. If error message con-
tinues, your range needs to be ser-
viced.
Safety Precautions & Key Points:
Cabinet Ventilation must be provided.
The inside temperature of the
cabinet must not exceed 90°F / 32° C. Regularly inspect air intake grill on
underside of ranges. Clean by vacuuming, as needed. The ventilation areas
into and out of the cabinet should be provided. Active ventilation may be
necessary dependent on cabinet design.
Actual range temperatures may vary due to a number of variables such as
ambient temperature in the immediate surrounding area, content and volume
of food being heated or cooked, and whether or not you are utilizing a cover
on the vessel you are using.
Never attempt to service any part of your MAX Induction® Range on your
own. Contact our Service Department by calling (1) 630-527-8600.
Attempting to service your Induction Range on your own, or through an
unauthorized repair facility automatically voids your warranty. For service
forms, visit the Spring USA Website.
For Limited Warranty Information, visit
www.springusa.com
Note:
This equipment uses, generates and can radiate radio frequency energy. If
not installed correctly and used in accordance with the instructions, may
cause harmful interference to radio communications. Users or guests with
Pacemakers should contact their health care professional prior to using this
product.