background image

 

 

DANGER: 

SPRAYING SYSTEMS CO. STRONGLY 

RECOMMENDS THE USE OF APPROPRIATE 

SAFETY EQUIPMENT WHEN WORKING WITH 

POTENTIALLY HAZARDOUS CHEMICALS. SEE YOUR 

CHEMICAL’S MSDS SHEET FOR ALL SAFETY MEASURES 

RELATING TO YOUR CHEMICAL.  

This equipment includes but is not limited to: 

 

Protective hat 

 

Safety glasses or face shield 

 

Chemical-resistant gloves and apron 

 

Long sleeve shirt and long pants 

Always remember to carefully read the chemical 

manufacturer’s label and follow all directions. 

WARNING: OPERATING MOTOR HAND-WHEEL 

NOTE: THAT UNDER NO CIRCUMSTANCES 

SHOULD ANY ADDITIONAL LEVER DEVICE SUCH 

AS A KEY WHEEL OR WRENCH BE APPLIED TO THE 

MOTOR HAND-WHEEL. THIS MAY CAUSE DAMAGE TO 

THE MOTOR OR THE TANK WASHER

.

 

MAINTENANCE

 

It is your responsibility to regularly inspect and make 

necessary repairs to this product in order to  

maintain proper operation.   

It is recommended that the bushings and seals be 

inspected every 1000 hours of operation or sooner  

if excessive leakage of the seals occurs. 

REMOVAL AND REPLACEMENT OF SPRAY NOZZLES 

(ITEM 30 ON PARTS LIST DRAWING PL 290E-EP) 

Make sure the unit is completely disconnected from the 

air source before attempting to service nozzles. 
1.

 

Unscrew spray nozzles (30) from nozzle hub (29) 

and inspect for plugging and wear. 

2.

 

If a nozzle is plugged or partially plugged, clean 

out the orifice and inlet area with a wooden 

toothpick or other relatively soft probe. 

Screwdrivers, wire or other hard metal items 

should not be used since they may scratch and 

severely damage the orifice. 

3.

 

If the nozzles need replacement, obtain new 

nozzles. 

4.

 

Replace spray nozzles (30) in nozzle hub (29) by 

tightly screwing them in. 

REMOVAL AND REPLACEMENT OF ELECTRIC MOTOR 

DRIVE (ITEM 13 ON PARTS LIST PL 290E-EP) 

1.

 

Unscrew (clockwise-left hand thread) rotary 

housing plug (31), and slide nozzle hub bushings 

(23) and nozzle hub (29) off the rotary housing 

(22). 

2.

 

Remove any foreign material from nozzle hub 

gear teeth. 

3.

 

To replace parts, slide one nozzle hub bushing 

(23) over the tube of rotary housing (22) up to 

the shoulder. 

4.

 

Insert second nozzle hub bushing (23) into nozzle 

hub (29) and push nozzle hub onto rotary 

housing tube. 

5.

 

Apply Loctite 243 or 242 to threads of rotary 

housing plug (31) and screw (counterclockwise) 

into rotary housing (29) until it seats firmly. 

6.

 

Torque to 150 lb-ft (203 Nm). 

REMOVAL AND REPLACEMENT OF ELECTRIC MOTOR 

(ITEM 1 ON PARTS LIST PL 290E-EP) 

1.

 

First make sure the unit is completely 

disconnected from the power source. 

2.

 

Unscrew both bolts (12) and lock washers (11). 

This will allow you to remove the motor  

sub-assembly (1). 

3.

 

Loosen set screw (3), slide motor coupler (4) 

from motor shaft to reveal key (2). 

4.

 

Reassemble in reverse order making sure that 

motor coupler (4) aligns with groove pin (7). 

REMOVAL/REPLACEMENT OF O-RINGS IN UPPER  

SHAFT SEAL BODY SUB-ASSEMBLY (5)  

(ON PARTS LIST PL 290E-EP) 

1.

 

If it has not already been done, remove the 

electric motor sub-assembly (1) per the  

previous instructions.  

2.

 

Carefully press out groove pin (7). 

3.

 

Loosen the upper shaft seal body sub-assembly 

(5) and remove it and gasket (6) from shaft. 

4.

 

Replace worn upper shaft seal body  

sub-assembly (5) with new sub-assembly (5). 

Содержание TankJet AA290E-EP Series

Страница 1: ...10 TankJet AA290E EP Series Tank Cleaner USER GUIDE spray com MI AA290E EP TankJet AA290E EP Electric Motor Driven Tank Cleaner ...

Страница 2: ...ufacturer s Operation Maintenance Manual is included with this tank washer as a separate manual since important safety precautions pertaining to the installation and operation of the motor itself are included SPECIFICATIONS Liquid Pressure 250 psi 17 bar max Flow Rates Up to 284 gpm 1075 l m Liquid Temperature 200 degrees F 93 degrees C max Electrical Motor 120 Volt AC or 240 Volt AC Tank Diameter...

Страница 3: ...3 DATA SHEETS ...

Страница 4: ...4 ...

Страница 5: ...ower supply to the conduit connection hole as shown on datasheet 290E EP and verify that the nozzle hub rotates clockwise when viewed from the nozzle hub end Connect the liquid line to the inlet connection of the liquid inlet body WIRING Route cabling through the most appropriate conduit entry making sure that cables will not foul on the cover assembly or internal components after refitting Refer ...

Страница 6: ...dup of static charge between the tank and the tank washer parts which could cause a sudden discharge of current with a resultant explosion or fire You may be killed or seriously injured if you do not follow these instructions HIGH IMPACT SPRAYS This tank washer may be equipped with solid stream nozzles which concentrate the flow energy into a small area for maximum impact and cleaning efficiency O...

Страница 7: ...d since they may scratch and severely damage the orifice 3 If the nozzles need replacement obtain new nozzles 4 Replace spray nozzles 30 in nozzle hub 29 by tightly screwing them in REMOVAL AND REPLACEMENT OF ELECTRIC MOTOR DRIVE ITEM 13 ON PARTS LIST PL 290E EP 1 Unscrew clockwise left hand thread rotary housing plug 31 and slide nozzle hub bushings 23 and nozzle hub 29 off the rotary housing 22 ...

Страница 8: ...ub assembly 20 Remove any foreign material from the bevel gear teeth 5 Remove worn bushings 23 and 21 from the rotary housing 22 6 Remove worn shaft bushing 26 and O ring 24 from the lower bushing retainer worn shaft bushing 25 and replace with new parts 7 Inspect shaft 13 for wear and replace shaft if worn 8 Reassemble unit by installing split bushing 21 nearest the gear 20 9 Hold split bushing 2...

Страница 9: ...9 PARTS LIST ...

Страница 10: ...10 MAINTENANCE RECORD Date Procedure Performed ...

Страница 11: ...ir 1996 components Hydraulics EN12100 1 Safety of machinery Basic concepts general principles 2003 for design Part 1 Basic terminology methodology EN12100 2 Safety of machinery Basic concepts general principles 2003 for design Part 2 Technical principles EN ISO 14121 1 Safety of machinery Risk assessment Part 1 Principles 2007 ASME B31 1 ASME Boiler and Pressure Vessel Code 2001 I hereby declare t...

Страница 12: ...North Avenue and Schmale Road P O Box 7900 Wheaton IL 60187 7901 Tel 1 800 95 SPRAY Intl Tel 1 630 665 5000 Fax 1 888 95 SPRAY Intl Fax 1 630 260 0842 www spray com MI AA290E EP Spraying Systems Co 2019 ...

Отзывы: