M
OUNTING
THE
DU
AND
CU
16
SpotCell® 100 Series
shows drip loops secured for both cables near the dual band (SC141/142) PCS DU.
Figure 4.6: Drip Loops for dual band PCS DU
When routing the cable on a roof be sure to locate it where it will not be tripped over.
Use tie-wraps to attach the cable to an existing pipe or cable run.
Figure 4.7: Cable Strap
Secure the cable to wood or siding walls using #6 x 1.5-in. wood screws and cable loop
straps as shown in Figure 4.7:.
To attach the cable to a brick or concrete wall:
1.
Drill a 3/16-in. diameter x 1-1/4 in. deep hole using a masonry drill bit.
2.
Insert the anchor flush with the mounting surface.
3.
Use cable clamps and screws to attach the cable to the wall.
4.3.5 Bringing the cable indoors
To bring the cable indoors, it may be necessary to drill a hole through the wall.
To bring the cable through an exterior wall:
1.
Depending on the material the wall is made of use a wood or masonry drill bit to drill
a 3/4-in. diameter hole.
2.
Pass the connector and cable through the wall.
3.
Use the putty/sealant provided to fill the hole.
Содержание spotcell 100
Страница 1: ...SpotCell 100 Series User Manual SpotCell 100 111 112 141 142 163 167...
Страница 2: ......
Страница 6: ...iv SpotCell 100 Series...
Страница 26: ...MOUNTING THE DU AND CU 20 SpotCell 100 Series...
Страница 34: ...TROUBLE SHOOTING 28 SpotCell 100 Series...
Страница 38: ...32 SpotCell100...
Страница 42: ...36 SpotCell111 112...
Страница 46: ...40 SpotCell163...
Страница 50: ...44 SpotCell167...
Страница 54: ...48 SpotCell141 142...
Страница 57: ...Notes...
Страница 58: ...Notes...
Страница 59: ...Notes...