RA 1
5
ELECTRICAL CONNECTIONS
The luminaire is designed to operate with a 100V to
240V supply, 50-60Hz, according to the lamp used.
Before and during the installation, make sure you follow
the guidelines below:
• Always check the earth wiring for the line being used.
• Verify that the lamp voltage is correct for the main
voltage
• Do not use lamps other than the ones indicated on
the lamp table
• There are no fuses inside the unit, if it is necessary
they should be installed in the mains
• The luminaires can be connected to a dimmer
INSERTING AND CHANGING THE LAMP
- Loose the knob
④
and rotate the accessory locking
cover
⑤
upwards
- Remove the safety net
②
- Replace the lamp without touching the glass bulb
- Insert the safety net again in its guides
- Re-place the accessory locking cover
⑤
and screw in
The accessory locking knob
④.
Please note that when changing the lamp, the position
of the luminaire fixture must not necessarily be
changed so that the focus of the luminaire fixture can
stay still.
DESCRIPTION OF THE LUMINAIRE
Referring to images on page 2:
①
Suspension yoke
②
Safety net
③
Accessory guides
④
Accessory locking knob
⑤
Accessory locking cover
⑥
Tilt adjustment knob
INTRODUCTION
The luminaire you have bought complies to 2006/95/EC,
2004/108/EC and 2011/65/EU European Directives.
The label on the rear of the luminaire lists the following
information:
• model
• mains supply voltage (V)
• lamp wattage (W)
• IP protection index
• maximum allowed ambient temperature in °C
• maximum temperature of the body in °C
• minimum distance from flammable surface
• information to find the position 0° of the luminaire:
when the tip of the arrow points upwards
• maximum tilt angle range. These limits, imposed by
the lamp manufacturer, should not be exceeded as
they would reduce the lamp’s useful life or lead to its
deterioration.
INSTALLATION
• The luminaires are intended for professional use only
so they have to be installed and used by qualified
technicians.
• The products are intended for indoor use:
consequently they have to be protected from humidity
and rain, if used in different conditions (IP 20)
• Do not mount the luminaire on or near a flammable
surface
• Please note carefully the notes written on the labels
of the luminaires.
• Do not forget to connect a safety cable, if required by
local country safety regulations
• For safety requirements the net shall be mounted
on the front of the lamp to prevent any large glass
fragments from falling in case of breaking.
• The luminaire can be either suspended or placed on a
plane surface.
WARNING: replace immediately the
lamp if visibly damaged, even if still
working.
WARNING: The luminaires must always be
earthed
WARNING: For safety reasons always discon-
nect the projector from the mains before
opening it to change the lamp.