MIDI CDM 250W
MIDI CDM 250W
INSERTING AND CHANGING THE LAMP
Open the luminaire lamp tray by pulling the knob
②
backwards
.
Remove the old lamp if installed, and insert the
appropriate new lamp bearing in mind that it can
be damaged by contact with the skin or other grasy
materials. Close the lamp holder tray, taking care it is
safety blocked.
• On cold start, the lamp will take a few minutes to
reach full brightness.
• Once switched off, wait approximately 10 minutes
before turning on again.
• Check the effective life-span of each lamp. Indeed,
it is necessary to replace the lamp (even if it still
works) when it has reached its maximum life time as
recommended by the manufacturer.
Using of the lamp beyond its recommended life time
considerably increases the risk of explosion.
• Use only lamps listed in the table on page 7.
6
FOCUS AND REGULATION
The luminaire should be at the minimum distance from
the object it is illuminating, as indicated on the label.
Using the side handle
⑥
it is possible to loosen the
luminaires when they are locked in a certain position
and thus change their inclination.
In the same way, the luminaires can be rotated with
respect to their vertical axis by rotating on their
hooking hinge.
By turning knob
⑧
the lamp carriage is shifted
forward or backward to widen or narrow the beam of
light respectively.
CLEANING
For utmost luminaire performance, both the lens and
the reflector must be periodically cleaned.
Always remember to disconnect the luminaire from the
mains and let the lamp cool before proceeding to any
cleaning or servicing operations.
MAINTENANCE
The luminaires must be serviced at least once a year to
check the integrity of their electrical and mechanical
parts. For this purpose, you should conctact only a
qualified dealer, to ensure proper service.
RECYCLING
The product must be recycled or disposed of,
according to Directive 2002/96/CE.
WARNING:
• For safety reasons always disconnect the
luminaire from the mains before opening
them to change the lamp
• Start off of high voltage lamp: never insert or
remove the lamp when fixture is powered on
• Never turn on the luminaire if the lamp and/or
lens is damaged to avoid UV trasmission and
the risk of explosion
• Let the lamp cool down completely
(approximately 10 min.) before opening the
luminaire.