Arc Video
CONTROL
•
On the top fix box:
- 1 XLR 5 pin male connector
⑧
is mounted to accept
DMX 512 signal for the control of the parameters of
the yoke,
(Dmx in)
- 1 XLR 5 pin female connector
⑨
is available to
transmit the DMX 512 signal to the next yoke
(Dmx
out).
- 1 cannon D 15 poles high density for SVGA signal
passing from the top of the yoke
⑦
to the side of
the projector
⑫
.
ELECTRICAL CONNECTION AND MAINTENANCE OF
VIDEO PROJECTOR
Please refer to the user manual of the video projector.
9
screws will not become slack with the time, or
because of the movement.
• Fix again the rectangular plate with the video
on the original position on the yoke, tightening
carefully the screws.
• If you are in doubt that the screws fixing the
projectors don’t give reasonable level of safety you
can use an extra fixation belt that ties up the video
to the plate from the front to the back.
• Finally if your video has no fixation screws at all,
you have to use two belts: one as above described
and another that is fixing the video along his cross
section.
• Don’t forget to check periodically that the screws
and the belt you have mounted are still well
tightened
ELECTRICAL CONNECTIONS
The product is foreseen for indoor use: consequently it
has to be protected from humidity and rain if used in
different conditions.
Verify that the unit voltage is correct for the main
voltage.
Always check the efficiency of the ground connection of
the electrical line you use.
POWER SUPPLY
Two independent electrical power supplies are foreseen
on the top fix box
•
projector power supply
②
:
230V 50/60 Hz 10A. Fuse is not foreseen on
the fixture and it has to be installed on the line
accordingly to the local specifications. This cable is
running inside the yoke and arrives close to the video
projector with IEC socket
⑪
.
•
motors and electronic boards power supply
①
:
2230V 50/60Hz 6A max: with IEC connector and 2
Amps fuse protection. It CANNOT be dimmed.
WARNING: The unit must always be earthed
WARNING
For safety reasons, always disconnect from
the mains supply before servicing.