47
EN
PROBLEM
POSSIBLE CAUSE
SUGGESTED ACTION
Treadmill will not start
Not plugged in
Plug cord into outlet
Safety Key not inserted
Insert Safety Key
Running belt not centered
Running belt tension not
correct on the left or right
sides of the running board
Tighten the adjustment bolts on the left
and right side of the rear roller.
Computer not working
Wires from the computer
and bottom control board not
properly connected.
Check wire connections
from the computer to the control board.
Transformer is damaged
If the transformer is damaged, contact
customer service.
E01 or E13: Message failure
Wires from the computer
and bottom control board not
properly connected.
Check wire connections from the
computer to the control board. If the wire
has been punctured or damaged, you will
need to replace it. If the problem is not
rectified, you may need to replace the
control board.
E02: Burst clash protection
Incoming voltage is lower than
50% of the required voltage.
Check that the incoming power supply is
the correct voltage.
E05: Current overload
protection
(Self Protecting System)
The incoming voltage is too
low or too high. The control
board is damaged.
Restart the treadmill. Check the incoming
voltage to ensure it is correct. Check the
control board, replace if damaged.
A moving part of the treadmill
is stuck and therefore the
motor is unable to rotate
properly.
Inspect moving parts of the treadmill to
ensure that they are operating correctly.
Check the motor, listen for strange noise
and check for a burning smell. Replace
the motor if necessary.
E06: Motor Abnormality
The motor wire is not
connected or the motor is
damaged.
Check motor wires to see if the motor
is connected. If the wire has been
punctured or damaged, you will need to
replace it. If the problem is not rectified,
you may need to replace the motor
E08: Control Board
Abnormality
The control board is not
connected.
Check the upper and middle wires to see
if the control board is connected. If the
wire has been punctured or damaged,
you will need to replace it. If the problem
is not rectified, you may need to replace
the control board.
E10: Motor Abnormality
The motor is damaged or a
moving part of the treadmill is
stuck and therefore the motor
is unable to rotate properly.
Inspect moving parts of the treadmill to
ensure that they are operating correctly.
Replace the motor if necessary.