Subsequent Use of this Generator 

 
For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation. 
 

IMPORTANT: Be familiar with the procedures described in the previous section titled “Using the Generator for the First Time” of this 
manual. If not, review this section now. 
 

Step 1 - Verify Oil Level 

 
It is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity. 
1. Verify that this generator is on a level surface. 

2. Unscrew the oil filler/dipstick cap from the engine. 

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap. 

4. Fully insert the dipstick without screwing the filler/dipstick cap and then remove again. There should be oil on the dipstick. If there is no oil on the 

dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See “Changing/Adding Oil” in the 

“Maintenance/Care” section of this manual). 

5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level. 
 

Step 2 - Verify Gas Level If Using Gasoline Fuel 

 

Before starting this generator, verify that there is sufficient gasoline in the fuel tank. If necessary, add fresh unleaded gasoline with an octane rating 
of 87 or higher according to “Step 2 - Add Gasoline” of the “Using this Generator for the First Time” section of this manual. 
 

Fuel Tank Capacity (gallons) 

4.5 

Fuel Type 

Fresh, Unleaded Gasoline Octane Rating 87 or Higher 

 

 
 
 
 

                               

                                                             

  

Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns.

 

• Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power 
tools, etc. 
• Always allow several minutes for the engine to cool before refueling. 
• Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a fire hazard and causes environmental 

damage. 
 

IMPORTANT: 

• Use only fresh UNLEADED gasoline with an octane rating of 87 or higher. 
• Never use old and/or contaminated gasoline. 
• Never use a mixture of oil and gasoline. 

• Avoid getting dirt and/or water in the fuel tank. 
• Never store generator for extended time with gasoline in the fuel tank. 
 

Step 3 - Ground the Generator 

 

                               

                                                            

   

Failure to properly ground this generator can result in electrocution.

 

 

Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable 
grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a 
copper or brass grounding rod that is driven into the earth. 
 
Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area. 
 

Содержание GEN4000IOF

Страница 1: ...ccur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT If you experience a proble...

Страница 2: ...22 ounces Fuel Capacity 4 5 gallon Fuel Type Unleaded Gasoline Only 87 rating or higher 3 800 RPM Mobility Kit Not Available If you are using a generator 3 000 feet above sea level it may not functio...

Страница 3: ...erify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 Overload Indicator 16 Economy Control Switch 16 AC Parallel 17...

Страница 4: ...ian to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous states exc...

Страница 5: ...Monoxide Gas When in operation the exhaust from this generator contains poisonous carbon monoxide gas Carbon monoxide gas is both odorless and colorless AND may be present even if you do not see or s...

Страница 6: ...grees Fahrenheit 65 Degrees Celsius Do not touch hot surfaces Observe all warning placards on this generator denoting hot surfaces Allow this generator to cool for several minutes after use before tou...

Страница 7: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 7...

Страница 8: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...enerator 9 PACKAGE CONTENTS The following item is supplied with this Generator Verify that it is included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for c...

Страница 10: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 10 GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator...

Страница 11: ...IF THE GENERATOR WILL NOT START DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine p...

Страница 12: ...TE Because gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Fuel Tank Capacity gallons 4...

Страница 13: ...an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Fuel Tank Capacity gallons 4 5 Fuel Type Fresh Unleaded Gasoline...

Страница 14: ...s felt Then pull briskly to start the engine Gently return the cord into the generator to avoid damage to the starter or housing Never allow the cord to snap back 7 If the engine fails to start repeat...

Страница 15: ...the rated wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated running wattage equal to or less than the ra...

Страница 16: ...1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15 1800 3600 NR 150 100 65 NR 20 2400 4800 175 125 75 50 NR 25 3000 6000 150 100 60 NR NR 30 3600 7200 125 65 NR...

Страница 17: ...black wire on left A and white wire on right B duplicate the same position on the opposite generator 3 Attach both ground connections on both control panels 4 Power up each generator with the Economy...

Страница 18: ...dule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat sparks and flame away Improper...

Страница 19: ...he oil should be changed after the first 20 hours of operation Subsequently the oil should be changed every 6 months or for every 100 hours of use or when the oil has become contaminated with water an...

Страница 20: ...park plug If it is cracked and or chipped discard and install a new spark plug A F7RTC Torch spark plug such as NGK BPR7ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap sh...

Страница 21: ...Care section Turn the fuel valve to the off position Disconnect the spark plug Do not obstruct any ventilation openings Do not drop or strike this generator while moving it Store this generator in a c...

Страница 22: ...off Pull the fuel line off The carburetor will slide off Turn the carburetor upside down and remove the 10mm bolt on the bottom of the bowl Remove the pin that holds the float on Pull the float up Ins...

Страница 23: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 23...

Страница 24: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 24 WIRING DIAGRAM...

Страница 25: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 25 PARTS DIAGRAM CRANKCASE ASSEMBLY...

Страница 26: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 26 CYLINDER HEAD...

Страница 27: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 27 CRANKSHAFT PISTON...

Страница 28: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 28 CAMSHAFT...

Страница 29: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 29 AIR CLEANER...

Страница 30: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 30 CARBURETOR...

Страница 31: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 31 RECOIL STARTER...

Страница 32: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 32 MUFFLER...

Страница 33: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 33 GENERATOR...

Страница 34: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 34 FUEL TANK...

Страница 35: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 35 FRAME...

Страница 36: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 36 INVERTER...

Страница 37: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 37 CONTROL PANEL...

Страница 38: ...ITEM GEN4000IOF Portable Gas Fuel Inverter Generator 38 ELECTRICAL SYSTEM...

Страница 39: ...ur failure to ensure the performance of all scheduled maintenance As the power equipment engine owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power equipm...

Страница 40: ...e used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of Buffalo Corp 10 Add on or modifie...

Отзывы: