STOPPING THE GENERATOR
To stop this generator:
1. Turn off all connected electrical devices and then unplug them.
2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.
3. If using gasoline, turn the fuel valve to the “OFF” position.
4. Set the engine power switch to the “OFF” position.
5. If using Propane, turn the propane tank fuel valve to the “off” position, then turn off the engine power switch.
Allow this generator to cool down before touching areas that become hot during operation.
Allowing gasoline to sit in this generator's fuel tank for extended time without use can increase the difficulty in starting this generator in
the future. Never store this generator for extended time with gasoline in the fuel tank.
MAINTENANCE/CARE
Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator
as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 7.
Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance
procedures. Keep heat, sparks and flame away.
Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause
death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual.
Recommended Maintenance Schedule
Each Use
Every Month or
Each 20 Hrs
Every 3 Months or
Each 50 Hrs
Every 6 Months or
Each 100 Hrs
Every Year or
Each 300 Hrs
Engine Oil
Check Level
X
Replace
X (first use)
X
Air Filter
Check
X
Clean
X
Spark Plug
Check/Clean
X
Fuel Tank
Verify Gas Level
X
Clean
X
Figure 7 - Recommended maintenance schedule
Cleaning the Generator
Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush,
vacuum and/or pressurized air.
Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion.
Never use gasoline to clean parts of this generator.
Содержание GEN3500DF
Страница 25: ...Item GEN351KIT30 Invertor Generators 25...
Страница 26: ...Item GEN351KIT30 Invertor Generators 26 PARTS DIAGRAM...
Страница 27: ...Item GEN351KIT30 Invertor Generators 27 PARTS DIAGRAM...
Страница 28: ...Item GEN351KIT30 Invertor Generators 28 PARTS DIAGRAM Valve Assembly...
Страница 29: ...Item GEN351KIT30 Invertor Generators 29 PARTS DIAGRAM...
Страница 30: ...Item GEN351KIT30 Invertor Generators 30 PARTS LIST...
Страница 44: ...Item GEN351KIT30 Invertor Generators 44 WIRING DIAGRAM...
Страница 45: ...Item GEN351KIT30 Invertor Generators 45...
Страница 46: ...Item GEN351KIT30 Invertor Generators 46...
Страница 47: ...Item GEN351KIT30 Invertor Generators 47...
Страница 48: ...Item GEN351KIT30 Invertor Generators 48...
Страница 49: ...Item GEN351KIT30 Invertor Generators 49...
Страница 50: ...Item GEN351KIT30 Invertor Generators 50...
Страница 51: ...Item GEN351KIT30 Invertor Generators 51...