Troubleshooting
Model:
T615
Malfunction:
Unit will not start operating.
Circumstance:
Turn POWER ON; the display does not light.
Possible cause:
Incoming power issue; component failure.
Troubleshooting: 1. Inspect the main fuse, power switch, & transformer
2. Inspect all cable connections.
3. Inspect drive board power LED. Or replace the drive
board as a test.
4. Inspect the display power LED and main IC.
5. Replace the SDC drive board.
3-2-1
Drive
Board
Display
Board
Filter
SW
FUSE
AC1
AC2
Transformer
Fuse holder & switch
Transformer voltage
Transformer
Voltage
(AC)
(red-red)
(blue-blue)
110V (red)
220V(blue)
black-black
12.5V
white-white
12.5V
orange-orange
29V
yellow-yellow
11.5V
LED2 Power
Cable connection
Program board