Troubleshooting
Model no. E875
Malfunction item: Bad HTR signal
Circumstance: Bad signal for HTR
Possible causes: 1. Bad HTR wiring
2.Bad HTR board
Troubleshooting: 1.Check wire connections on the display
2. Check HTR wire connections on the drive board
3. Check HTR bridge board for HTR signal
4. Check HTR sensors and grounding
3-4-2
Display
board
HTR board
S
e
n
so
r-
R
S
e
n
so
r-
L
HTR board
HTR board indicators
LED
Name
Description
LED1
POLAR indicator
Light flashing = Polar signal working
LED2
HTR indicator
Light up = hands on the HTR sensors
LED3
HTR indicator
Light flashing = HTR signal working
LED4
Heart rate signal
output indicator
Each light flash = 1 heart beat signal
output
HTR wiring
HTR connectors