SP20 Jackson Quick Start Guide
Installing your SP20 Jackson
Version 2.0
6
3.2
Specifications
Electrical
Refer to the SP20 Jackson Power Supply Selection Guide for detailed power supply electrical specifications.
Acoustic Noise
Nominal fan speed:
Front (1m distance): 63dB
Rear (1m distance): 67dB
4
Installing your SP20 Jackson
Do not operate the unit in an area that exceeds 40 °C (104 °F).
Enable sufficient airflow by giving clearance of at least 50 cm (20") around the ventilation
openings at the front and rear of the unit.
4.1
Prerequisites
Before installing the SP20 Jackson ensure you have the following:
PSU
CAT 5e or higher Ethernet cable
Local switch/router with an Internet connection
Bitcoin wallet with public key
Bitcoin pool membership (this may also be defined while configuring the SP20 Jackson, as explained in
Section 5.2 below).
4.2
Installation Procedure
1.
Place the SP20 Jackson on a flat surface.
2.
Connect one end of the CAT 5e Ethernet cable to a local switch/router, then connect the other end to the
Ethernet port on the SP20 Jackson front panel.
3.
Connect the power cable 6-pin PCIe connectors to the SP20 Jackson power ports, then connect the other end of
the power cable to the PSU.
4.
Connect the PSU to a suitable electrical outlet.
4.3
Shutting Down
To shut down the SP20 Jackson, disconnect the AC power cord from each PSU.