IP Network Intercom Terminal Installation Instructions
1
"123456".
(
2
)
From the right menu choose
【
Mandatory method configuration
】
, then fill in the
correct parameters in the
【
terminal parameters
】
, click "send parameters" button to
complete the IP parameters Setting.
Specification
、
Function unit& Parameter
Power voltage
DC12V
Consumption
≤5W
Interface
Network input Alarm input Alarm output Power input
Audio output
Support network protocol TCP/IP
、
UDP
、
ARP
、
ICMP
、
IGMP protocol
Network chip rating
10/100Mbps
Audio sampling
8kHz
~
22.050kHz, 16bit
Transmit rate
16kbps-352kbps
SNR
>90dB
Frequency response
20Hz-16KHz
Malfunction Test
Fault phenomenon
Reason& trouble removal
Why it appear "terminal
network services (UDP) start
fail" warning in the process of
starting server software?
Appearing this warning information, it’s usually the
local server network connection has been
disconnected, please connect the local network
cable well and exit the software, then restart it.
Why scanning tools can’t find
the terminal?
1. It`s required to close all firewalls or with data
interception function software before open the
software server
2. Network card do not compatible with terminal.
3. Using other computer to scan the machine.
Packing List
IP Network Intercom Terminal Installation Instructions
2