background image

                                                                

IP network active speaker User Manual

 

Summarize 

Safety precaution 

Please abide by the warning and the relevant safety tips. 

Please take this manual in convenient place after you reading the guide for future reference. 

 

Warning 

  

The sign means there is potential safety hazard, when operate wrong may result in death or serious injury.

 

  

The sign is used to remind the user that attached is the important operation and maintenance data. 

 

Setting and Installation 

1

Avoid being wet with the water. 

Don’t make the machine or exposed to rain water or other liquid contamination of the environment, or lead to fire or get an 

electric shock. 

2

Don’t use unspecified voltage. 

Using the marked voltage on the machine. 

Using more than the logo of voltage could lead to fire or shock. 

3

Don’t scratch the power cord. 

Don’t scratch the power cord or cut it. 

Simultaneous, keep the power line far way from heated objects, put heavy things on it will lead to fires or electric shock. 

 

Using machine 

1

In case of the anomalies 

Please turn off the power supply immediately when finding the abnormal phenomena, please connect with the agency.if you 

continue to use, it will likely fires or shock. 

·The smoke or odor of the machine. 

·The inside of the machine is flooded by water or foreign bodies intrusion. 

·Machine falling or machine shell damage. 

·The power cord damage(wire core is exposed of broken, etc) 

·Fault(eg: it can’t network, no sound ..etc) 

2

Don’t open the machine internal or modify the machine 

Do not let foreign matters invade the machines internal. 

Don’t let the metal items or inflammable objects inserting machine such as foreign inserting machines or throw into the vents 

machines internal, otherwise will likely cause fires or electric shock. 

3

Please do not touch it when thundering 

To avoid electric shock, please do not touch the machine and the plug when lightning, etc. 

4

Please do not place containers with liquid or small metal objects on machine above 

If gets upset containers, and let the fluid inflow to the machine that will likely fires or cause shock. 

5

Do not open the machine internal or modify the machine 

The machine internal contains high voltage parts, once open the cover or modify the machine, it will likely fires or cause shock. 

All the maintenance and other machine modification should be operated by professional personnel. 

6

Maintenance and the precautions for not using in a long time 

While maintenance, if the machine is not using for 10 days or more , please shut off power supply switch for safety. If do not 

comply with this provision, it will likely cause electric shock or fires. 

                                                                                         1 

Содержание NAS-8507A

Страница 1: ...IP network active speaker User Manual ...

Страница 2: ...e wireless channel select 2 4G wireless module is available 7 Language Setting 7 Audio parameters 8 Audio automatic detection function 9 Wireless amplification sampling rate 2 4G wireless module is available 9 Constant voltage backup constant voltage backup module is available 9 Password Setting 9 Reboot Device 10 Restore Factory Setting 10 Firmware Upgrade 10 Receive broadcasting 10 Other functio...

Страница 3: ...machine The inside of the machine is flooded by water or foreign bodies intrusion Machine falling or machine shell damage The power cord damage wire core is exposed of broken etc Fault eg it can t network no sound etc 2 Don t open the machine internal or modify the machine Do not let foreign matters invade the machines internal Don t let the metal items or inflammable objects inserting machine suc...

Страница 4: ...iver work cooperatively optional Support constant voltage backup module access to 100V constant voltage broadcast line as backup when net work abnormal IP network active speakers can automatically or manually switch from digital network broadcast ing to constant voltage broadcasting optional Hardware Interface Introduction Back DC24V power input interface STATE status indicator the different indic...

Страница 5: ... force update status press this butt on will play the terminal IP and subnet mask information DRC Dynamic range compression Support DRC dynamic range compression make the output amplitude match the speaker dynamic range thus reduc ing the clipping and distortion caused by excessive volume In addition the DRC function also can protect the spea ker under high power from being damaged soit can effect...

Страница 6: ...s For deputy speaker use only 8 Quick installation guide 1pcs 9 Certification 1pcs Wiring 1 Connect one port of the power adapter with IP network active speaker power interface the other one connect to the outlet 2 Connect one port of Ethernet Cable with IP network active speaker cable interface the other one connect to switcher 3 Connect the other devices with corresponding interface respectively...

Страница 7: ...ng Tools 1 From CD tools directory to find and run IP configuration tool audio terminal after start it please enter the default password 123456 2 From the right menu choose Mandatory config then fill the correct parametersin the terminal parameters click send parameters button to complete the IP parameters Settings Note 1 Please use the administrator mode to run and close the firewall or other rel...

Страница 8: ...rameters according to the environment after setting completed click save Specific operation steps please refer to custom terminal parameters in the network settings User define terminal parameters Login web interface 1 Please input the IP network active speaker to the address column of the browser the factory default IP address is 192 168 1 101 then enter 2 Enter the user name and password in the ...

Страница 9: ...s is 192 168 1 101 Note It can t revise except with the special situation The default is 2046 Subnet mask The subnet mask of the terminal Default gateway The network gateway of the terminal Preferred DNS server The preferred domain name interpreter IP of terminal Alternate DNS server The standby domain name interpreter IP of terminal Version server Version server IP terminal can connect the versio...

Страница 10: ...00Hz 22050Hz Intercom output volume IP network active speaker total output volume of intercom 0 15 6 grade is 0dB Broadcast sampling rate IP network active speaker sampling rate of broadcasting 8000Hz 22050Hz Broadcast output volume IP network active speaker total output volume of broadcasting0 15 6 grade is 0dB Audio priority It can select local and network priority the default is network priorit...

Страница 11: ... will be closed with 1 min Line input threshold is set from audio parameters in web page The audio range lowest level requirements is grade one the highest is grade five Wireless amplification sampling rate 2 4G wireless module is available In web page audio parameters can select different wireless amplification sampling rate select the remote distance can acquire further transmission distance sel...

Страница 12: ...ls firmware upgrade click enter the firmware upgrade mode button to enter the firmware update WEB page then choose the factory offered firmware update file click firmware upgrade button to upgrade Receive broadcasting Automatically answer without pressing any button Other functions In addition to the above functions IP network active speaker can cooperate with the server to realize timing ringing ...

Страница 13: ...the terminal network cable and switcher whether they work normal damaged and disconnect or not etc 3 Check the terminal IP setting Please check the terminal ID sever IP local IP gateway IP etc parameters How to solve the warning of terminal network service UDP failed during the process of the starting the service software Server local network connection is disconnected connect the local network ca...

Страница 14: ...ment can not be modified and for commercial uses If any damage and losses which is caused by illegality modify and switch the document SOPN shall not take any responsibility Guarantee Regarding to the information of the mentioned handbook if any modify kindly understand that there is no any notice The handbook shall provide the correct indication information and suggestion and not guarantee to any...

Отзывы: