14
pH sensor
Operating temperature: 0-60degC
pH Range: 0-14 pH
Slope: >98%
pH sensor: Glass Bullet
Accuracy: +- 0.1 pH unit
ORP sensor
Operating Temperature: 0-60degC
ORP Range: +-2000mV
ORP Sensor: 99.9% Pure Gold 4mm x1mm Pin
Accuracy: +-50mV
Temperature sensor
Operating Temperature: -20 - +80degC
Temp Sensor: 316 Marine grade stainless steel
Accuracy: +/- 3 degree C
Flow sensor
Operating Temperature: 0-80degC
Flow Range: 20-600 Lpm
Bearing Material: Zirconium
Accuracy: +/- 8 Lpm
Pressure sensor
Operating Temperature: -40 - +125degC
Pressure Range: 0-500 kPa
Sensor Type: Monolithic
Sensor Material: Ceramic
Accuracy: +/- 8 kPa