Installation Instructions
1. Disconnect the power source
2. Use the security hex key supplied and turn the cover mounting screws
clockwise to remove the cover from the dryer.
3. Place the hand dryer base on the wall at the desired location using Table 1 to
determine the recommended mounting height. With the base so located, use it
as a template to mark locations of the four mounting bolt holes on the wall.
Ensure that no reflective object (such as hand basin) is located directly
under infra
-
red sensor eye; the minimum distance is 460mm.
4. Fasten the base to the wall, using suitable fixings for the type of wall.
5. All automatic dryers must have their own dedicated 10 amp circuit.
6. Connect the dryer to the nearest suitable distribution panel.
7. Replace cover, turn screws counter
-
clockwise making certain not to over
tighten.
IMPORTANT: Consult local and general regulations before performing dryer
installation.
CLEANING INSTRUCTIONS
Read complete instruction before proceeding. Under normal use, cleaning the dryer once
a year will keep it in good operating condition. If the washroom traffic is heavier than
normal the cleaning should be done every 4 to 6 months. Lint and dust build up on the
motor inlet filter can result in damage to motor or over temperature tripping, new filters
are available, part #WDFA
PLEASE NOTE: A severely clogged filter will reduce motor life and could void the
warranty.
1. Turn off dryer at circuit breaker or fuse panel.
2. Turn the cover mounting screws clockwise from the dryer using the security hex key
provided. Support cover while removing screws.
3. Vacuum out dirt from blower and housing. Use caution not to damage wires or circuit
boards.
4. The motor inlet cover may be removed by unscrewing the (4) screws. This allows
access to the motor for cleaning or replacement.
5. Use a soft–
medium bristle 10mm paint brush to clean dust and dirt from motor.
6. Replace cover. Place cover squarely over base and push flush to wall. Screw cover
mounting screws counter
-
clockwise and tighten until snug. Do not over tighten.
General Safety Information
DANGER
Failure to disconnect the power source before installation can result in
serious injury or death from electric shock.
-
Always disconnect the power source before servicing or installing the hand dryer.
DANGER
Failure to properly ground this unit could result in severe electrical
shock and/or death
-
This hand dryer must be properly grounded (Earthed) for safe operation. An identified
ground connection point is supplied on the chassis of the hand dryer.
-
We recommend GFCI protection in wet or damp locations or as required by local
code.
WARNING
Risk of fire. Personal injury or property damage are possible if local
codes, or safety recommendations are not followed.
Installation must be carried out by a qualified person in accordance with all local wiring
regulations
Fixed wiring is recommended for all installations. Wiring should emerge from the wall in
the position marked on the mounting diagram. All fixed wiring should incorporate a
switch or breaker with a contract separation of at least 3mm in all poles.
CAUTION
Improper mounting could result in personal injury or property damage
-
Follow the mounting recommendations in Table 1.
-
On a stud wall, one side of the hand dryer should be mounted to an existing stud.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Table 1
Recommended Mounting Heights from Floor to Dryer Bottom Edge
Men
’
s washroom
1100mm
Ladies
’
washroom
1050mm
Children
’
s washroom
13
-
17yrs
1000mm
Children
’
s washroom
10
-
13yrs
950mm
Children
’
s washroom
7
-
10yrs
900mm
Children
’
s washroom
4
-
7yrs
800mm
Disabled Person
’
s
950mm
Fasten dryer to the wall using suitable fixings for the type of wall.