SPL Supreme AIRFORCE Скачать руководство пользователя страница 3

Installation Instructions 

 

 

1. Disconnect the power source

 

2. Use the security hex key supplied and turn the cover mounting screws

 

    clockwise to remove the cover from the dryer.

 

3. Place the hand dryer base on the wall at the desired location using Table 1 to

 

    determine the recommended mounting height. With the base so located, use it

 

    as a template to mark locations of the four mounting bolt holes on the wall.

 

    

Ensure that no reflective object (such as hand basin) is located directly 

 

    under infra

-

red sensor eye; the minimum distance is 460mm.

 

4. Fasten the base to the wall, using suitable fixings for the type of wall. 

 

5. All automatic dryers must have their own dedicated 10 amp circuit.

 

6. Connect the dryer to the nearest suitable distribution panel.

 

7. Replace cover, turn screws counter

-

clockwise making certain not to over 

 

    tighten. 

 

 

IMPORTANT: Consult local and general regulations before performing dryer

 

installation. 

 

 

CLEANING INSTRUCTIONS

 

Read complete instruction before proceeding. Under normal use, cleaning the dryer once 

a year will keep it in good operating condition. If the washroom traffic is heavier than 

 

normal the cleaning should be done every 4 to 6 months. Lint and dust build up on the 

motor inlet filter can result in damage to motor or over temperature tripping, new filters 

are available, part #WDFA

 

 

PLEASE NOTE: A severely clogged filter will reduce motor life and could void the      

warranty. 

 

 

1. Turn off dryer at circuit breaker or fuse panel.

 

2. Turn the cover mounting screws clockwise from the dryer using the security hex key 

 

    provided. Support cover while removing screws.

 

3. Vacuum out dirt from blower and housing. Use caution not to damage wires or circuit  

 

    boards.

 

4. The motor inlet cover may be removed by unscrewing the (4) screws. This allows 

 

    access to the motor for cleaning or replacement.

 

5. Use a soft–

 

medium bristle 10mm paint brush to clean dust and dirt from motor.

 

6. Replace cover. Place cover squarely over base and push flush to wall. Screw cover

 

   mounting screws counter

-

clockwise and tighten until snug. Do not over tighten.

 

General Safety Information

 

DANGER  

Failure to disconnect the power source before installation can result in 

serious injury or death from electric shock.

 

-

Always disconnect the power source before servicing or installing the hand dryer.

 

 

DANGER  

Failure to properly ground this unit could result in severe electrical 

shock and/or death

 

 

-

This hand dryer must be properly grounded (Earthed) for safe operation. An identified

 

 ground connection point is supplied on the chassis of the hand dryer. 

 

-

We recommend GFCI protection in wet or damp locations or as required by local

 

 code.

 

 

WARNING  

Risk of fire. Personal injury or property damage are possible if local 

codes, or safety recommendations are not followed. 

 

 

Installation must be carried out by a qualified person in accordance with all local wiring 

regulations

 

Fixed wiring is recommended for all installations. Wiring should emerge from the wall in 

the position marked on the mounting diagram. All fixed wiring should incorporate a 

switch or breaker with a contract separation of at least 3mm in all poles. 

 

 

CAUTION  

Improper mounting could result in personal injury or property damage

 

-

Follow the mounting recommendations in Table 1.

 

-

On a stud wall, one side of the hand dryer should be mounted to an existing stud.

 

 

This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety. 

 

Table 1

 

Recommended Mounting Heights from Floor to Dryer Bottom Edge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                     

 

 

 

Men

s washroom

 

 

 

 

1100mm

 

Ladies

’ 

washroom

   

 

 

1050mm

 

Children

s washroom

  

13

-

17yrs

 

1000mm

 

Children

s washroom

  

10

-

13yrs

 

950mm

 

Children

s washroom

  

7

-

10yrs

 

900mm

 

Children

s washroom

  

4

-

7yrs

  

800mm

 

Disabled Person

s

   

 

 

950mm

 

 

Fasten dryer to the wall using suitable fixings for the type of wall. 

 

Fixing to at least one stud is recommended where possible. 

 

Отзывы: