background image

10

S T E R E O

5.

A section within the S

TEREO

V

ITALIZER

with one of the most decisive

influences on the sound is P

ROCESS

control. If you continue to turn the

P

ROCESS

control up, more of the signal is added to the B

ASS

and M

ID

-H

I

T

UNE

sections whilst dominant mid frequencies are reduced according human

hearing at the same time. The below sections contain more detailed infor-

mation on this aspect. Familiarize yourself with the sound changes before

deciding on the setting which sounds best.

6.

We shall now turn our attention to the H

ARMONICS

control. Note the

improved detail in the high frequency range, the further you turn the

control in. In practice, values between 4 and 6 have proved to be the most

common.

The H

ARMONICS

are accentuated by the S

TEREO

V

ITALIZER

with equalizer

technology, unlike other procedures. Previously, so-called »Exciters«,

devices to generate harmonic tones, produced their harmonics with the aid

of a generator which mainly added type K3 and type K5 distortions to the

signal (odd harmonics of 3rd and 5th order). The familiar disadvantages of

this principle are as follows: although odd harmonics do add to the brilli-

ance of the audio signal to a significant degree, they tend to be somewhat

sharp, which leeds to hearing fatigue for listeners. Another pitfall is that the

distortions added were not part of the original signal.

The S

TEREO

V

ITALIZER

accentuates the harmonics which are also part of the

original signal! The H

ARMONICS

filters are designed in such a way that even

and odd harmonics (K2, K3, K4, K5...) are accentuated equally. This makes

the processed signal more natural with a soft, silky-sounding top-end.

Once you have selected the setting for the 

HARMONICS

control you can sit

back to listen to the new sound image.

7.

Finally, activate the S

URROUND

P

ROCESSOR

turn up the S

TEREO

W

IDTH

control to the 12h-position and note the soft spreading stereo image. 

8.

Switch V

ITALIZER

A

CTIVE

off to return to the original signal. If you now

say »I don't believe that« or »Booh«, you belong to the overwhelming

majority of those people who have ever heard a V

ITALIZER

. It was this sound

impression which led to V

ITALIZER

technology winning awards like the

»Golden Ear« from Europe's biggest »Audio« magazine for the most inno-

vative product in 1993.

First steps

Содержание STEREO VITALIZER 9320

Страница 1: ...Owner s Manual SOUND PERFORMANCE LABORATORY STEREO Models 9319 9320...

Страница 2: ...ons of Liability In no event will SPL be liable for any damages including loss of data lost profits cost of cover or other special incidental consequential or indirect damages arising from the use of...

Страница 3: ...ssors currently available The STEREO VITALIZER is a first rate sound processor with exemplary performance excellent work manship and unrivalled sound quality Please study this owner s manual carefully...

Страница 4: ...w transparent and powerful almost every audio signal sounds after it has been processed with the STEREO VITALIZER The housing of the STEREO VITALIZER has the standard 19 EIA format and occupies 1 unit...

Страница 5: ...Two positions are available The LOW position indicates that the input sensitivity of the STEREO VITALIZER is low which means high level signals can be processed at this position Conversely the HIGH p...

Страница 6: ...rdings played through the same monitor system Do not connect the STEREO VITALIZER between master outputs and amplifier The major disadvantage of this connection is the varying input sensitivity with e...

Страница 7: ...to compen sate for deficiencies in the copying system It may also be necessary to modify the bass end as many high speed systems fail to reproduce the bass end of the spectrum faithfully In both areas...

Страница 8: ...oundtracks benefit in the ways already described for audio only applications and the fact that the STEREO VITALIZER is so quick to set up can save a lot of wasted time spent tuning multi band equalize...

Страница 9: ...to the right The bass sounds tight and dry Turn to the left The bass sounds soft and round You should perform these hearing tests on appropriate full range monitors because near field monitors normall...

Страница 10: ...e familiar disadvantages of this principle are as follows although odd harmonics do add to the brilli ance of the audio signal to a significant degree they tend to be somewhat sharp which leeds to hea...

Страница 11: ...only light up briefly if at all It is essential to avoid the PEAK LEDs being lit up for any length of time If they do so reduce the input level or switch from LOW to HIGH on the rear of the unit The B...

Страница 12: ...a different bass structure than with a lower bass amplification combined with a higher PROCESS value Choosing the best solution is a matter of personal taste and also depends on the type of original s...

Страница 13: ...lower frequencies The further down you go the brighter the sound image becomes as an increasing number of frequencies are included in the process The MID HI TUNE control can also be used to tone down...

Страница 14: ...le of Exciters The STEREO VITALIZER s harmonic filter does not add any distortions to the original signal unlike with the generator principle It extracts all the infor mation it needs from the origina...

Страница 15: ...he integral power supply is designed to minimize induced hum and noise due to the non existence of an air gap On the XLR jack version 9320 the primary voltage may be selected between 230V 50Hz and 115...

Страница 16: ...uency range 15 Hz 22 kHz CMRR common mode rejection 85dBu at 100 Hz 76dBu at 1 kHz 65dBu at 15 kHz THD N total harmonic distortion noise 0 002 at 1 kHz 0 105 at 10kHz Signal to noise CCIR 468 Bypass 9...

Страница 17: ...ized SPL warranty repair facility in the country where purchased or to the SPL factory in Germany in the original packaging or a replacement supplied by SPL with all transportation costs and full insu...

Отзывы: